Harmonics Currents Cancelation by Three-Phase 4-wire Hybrid Active Power Filter with Split Capacitors and STF

Abstract

The quality of electrical power is the major important goal of all researchers. In utility power system it has been observed that harmonics build a major role in reducing the quality power. These harmonics caused by nonlinear loads. Many consumers appliances demand quality power continuously for their operation. The performance of the end user equipment is heavily dependent on the quality of power supplied to it. This power is affected by various external and internal factors. They are like voltage and frequency variations, faults, outages etc. The solution to overcome these problems is to filter out these harmonics. For this purpose, there are many filters topologies are proposed and studied in the literature to eliminate harmonics currents. In this paper, three phase 4-wire hybrid filter is proposed with Self-Tuning-Filter (STF).in this paper, a hybrid power filter is proposed to solve problems of line harmonic currents and neutral line currents of three phase four wire power distribution system. The hybrid filter is three-arm power converter with split capacitors. This configuration uses a smaller number of power electronic switches to reduce the manufacturing cost. The use of STF in the control method can optimize the performance of this topology regarding to classical one. The proposed control strategy is simulated in MATLAB Simulink and the results are presented.

Authors and Affiliations

Mohamed Muftah Saleem Abdusalam

Keywords

.

Related Articles

Asynchronous Motor Control Using Control Panel

Recently programmable logic controllers and control panels have frequently been started using together. The control panels allow the operator to monitor and control all inputs and outputs connected to the programmable co...

Closed Loop Control of Composite Dc-Dc Converter for Electric Vehicle

In a electric vehicle powertrain, a boost dc-dc converter enables reduction of the size of the electric machine and optimization of the battery system. Design of the powertrain boost converter is challenging because the...

Orbit Analysis For Imbalance Fault Detection In Rotating Machinery

Analysis of the axis orbit is extremely important for monitoring faults in rotary machines and making an associated diagnosis for repair. The development of both experimental procedures based on implementation of instrum...

Comparative analysis of various asymmetrical configurations of cascaded H-Bridge multilevel converter

The main objective of asymmetrical multilevel converter configuration is to achieve quality form of AC voltage and current by increasing the levels of output voltage. This paper mainly investigate the pro’s and cod’s of...

Mechatronic Control Model of an inverted pendulum

The inverted pendulum, a popular mechatronic application, is considered as a special class of unstable, non-linear, multivariable and complex mechatronic systems with two degrees of freedom and a single control input. Th...

Download PDF file
  • EP ID EP421917
  • DOI 10.9790/1676-1306010106.
  • Views 128
  • Downloads 0

How To Cite

Mohamed Muftah Saleem Abdusalam (2018). Harmonics Currents Cancelation by Three-Phase 4-wire Hybrid Active Power Filter with Split Capacitors and STF. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(6), 1-6. https://europub.co.uk/articles/-A-421917