HbA2 ölçümü için BioRad D-10TM ve Tosoh HLC 723 G8 HPLC sistemlerinin karşılaştırılması (Comparison of the BioRad D-10TM and Tosoh HLC 723 G8 HPLC instruments for the detection of HbA2)
Journal Title: Turk Hijyen ve Deneysel Biyoloji Dergisi - Year 2016, Vol 73, Issue 3
Abstract
Amaç: Özellikle Akdeniz bölgesinde önemli bir halk sağlığı sorunu olan hemoglobin bozuklukları taramasında hemoglobin sub tiplerini ayırt etmek amacıyla en yaygın kullanılan yöntem HPLC (High Performance Liquid Chromatography)’dir. Pek çok marka ve model HPLC sistemleri ile hemoglobinopati taraması yapılmakta ancak sistemlerin birbirleri ile uyumu bilinmemektedir. Bu çalışmanın amacı; D-10TM Hemoglobin testingsystem (BioRad,Hercules,USA) marka HPLC cihazı ile Tosoh HLC 723 G8 (TosohBioscience, Japan) HPLC cihazını hemoglobinopati tanı ve taraması açısından önemli olan HbA2 parametresi ölçümü bakımından karşılaştırılmasıdır. Yöntemler: Çalışmaya Antalya Eğitim ve Araştırma Hastanesi Merkez Laboratuvarı Biyokimya Bölümüne 1-31 Ocak 2016 tarihleri arasında talasemi taraması için başvuran 12’si erkek, 18’i kadın toplam 30 kişi alındı. Her iki cihazda tek seferde çalışılan hemoglobin A2 (HbA2) değerlerinin farkları için bağımlı iki grup ve iki ölçüm fark testleri, istatistiksel uyum ve ilişki analizi için iki-yönlü rastgele sınıf içi korelasyon katsayısı (SKK), Cohen’s kappa katsayısı, korelasyon katsayısı (r) ve Bland Altman Analizi yapıldı. Sonuçlar uygun grafiklerle sunuldu. Bulgular: Analizler sonucunda Tosoh HLC 723 G8 cihazında örneklerin 14’ü (%46.66) ve BioRad D-10TM cihazında örneklerin dokuz’u (%30) β -talasemi taşıyıcısı olarak saptandı. Her iki cihazda ölçülen HbA2 değerleri arasında anlamlı fark saptandı (z= -4.487; p <0.001). HbA2 değerleri için sınıf içi korelasyon katsayısı 0.898, uyum katsayısı 0.783, Spearman korelasyon katsayısı 0.944, Cohen’s Kappa değeri 0.658 ve Bland Altman Analizi sonucu yanlılık değeri 0.75 (Alt Limit: -0.49; Üst Limit: 1.99) olarak bulundu. Sonuç: Korelasyon, regresyon ve diğer istatistiksel analizlere göre her iki cihaz arasındaki uyum yetersiz olarak bulundu. Objective: HPLC (High Performance Liquid Chromatography) is the most commonly used method to differentiate the subtypes of hemoglobin in screening for hemoglobinopathy which is a major public health care problem especially in Mediterranean region. Today, different models and trademarks of HPLC equipment have been used in screening for hemoglobinopathy. However, the agreement of the results of the analyses performed by these types of equipment are unknown. In this study, the aim was to investigate the agreement between the results of the analyses of HbA2 values with D-10TM Hemoglobin testing system (BioRad,Hercules,USA) and Tosoh HLC 723 G8 (TosohBioscience, Japan) trademark. Methods: A total of 30 individuals, 12 males and 18 females, applied to the Antalya Training and Research Hospital laboratory between January 1 and January 31, 2016 for thalassemia screening were included to this study. Statistical correlations of hemoglobin A2 (HbA2) values, analyzed in each analyzer as a single analysis from each sample, were evaluated using two-way random intraclass correlation coefficient (ICC), Cohen’s kappa coefficient, correlation coefficient (r) and Bland Altman analysis. Results are presented with graphics. Results: As a result of the analysis, 14 of the samples (46.66%) were detected as – thalassemia carrier with Tosoh HLC 723 G8 system and nine of the samples (30%) were detected as – thalassemia carrier with BioRad D-10TM system. There was significant differance in HbA2 values measured with both systems (z= -4.487; p <0.001). For HbA2 values; intraclass correlation coefficient was 0.898, coefficeint of concordance was 0.783, Spearman corelation coefficiency was 0.944, Cohen’s Kappa value 0.658 and Bland Altman analysis bias value was 0.75 (LowerLimit: -0.49; Upper Limit: 1.99). Conclusion: According to the regression, correlation and other statistical analyses, agreement between the results of HbA2 values measured by the two analyzers were found to be insufficient.
Authors and Affiliations
Güzin AYKAL, Fazıla ATAKAN-ERKAL, Ayşenur YEĞİN, Esin EREN, Necat YILMAZ
Çeşitli klinik örneklerden 2006-2011 yılları arasında izole edilen Acinetobacter türleri ve antibiyotik duyarlılıkları (Acinetobacter species isolated from various clinical specimens between 2006-2011 years and their susceptibilities against antibiotics)
Amaç: Son altı yılda, hastanemizde izole edilen Acinetobacter türlerinin dağılımı ve antibiyotik duyarlılıklarının incelenmesi amaçlanmıştır. Yöntem: Çalışmaya; Ondokuz Mayıs Üniversitesi Tıp Fakültesi Hastanesi Merkez L...
Psychoda albipennis’e bağlı tekrarlayan üriner miyazis (Recurrent urinary myiasis caused by Psychoda albipennis)
Miyazis canlı insan ve vertebralı hayvanların, çeşitli sinek türlerinin larvaları tarafından istilası olarak tanımlanır. Tropikal ve subtropikal ülkelerde insanlarda miyazise neden olduğu bilinen sineklerin 50’den fazla...
The presence and distribution of high risk HPV types in simultaneous cervical cytology samples (Eş zamanlı servikal sitoloji örneklerinde yüksek riskli HPV tiplerinin varlığı ve dağılımı)
Objective: Human papillomavirus (HPV) is the most detected viral pathogen of reproductive system and almost all servical carsinomas are related to HPV. The incidance and mortality rate of cervical carsinomas are signific...
Akharım beldesinde musluk suyu kaynaklı gastroenterit salgını, Afyonkarahisar ili, Türkiye, Mayıs 2014 (A gastroenteritis outbreak caused by contaminated tap water, Akharim town, Afyonkarahisar province, Turkey, May 2014.)
Amaç: 8 Mayıs 2014 tarihinde, Afyonkarahisar Halk Sağlığı Müdürlüğü tarafından; Sandıklı ilçesi Akharım beldesinde, gastroenterit vakalarında artış olduğu ve 395 kişinin sağlık kuruluşlarına başvurduğu bildirilmiştir. Ça...
Manisa ili hepatit A seronegatifliği ve sosyal belirleyicilerle ilişkisi, 2014 (Hepatitis A seronegativity and its relationship with social determinants in Manisa province, 2014)
Amaç: Bu araştırmada 2014 yılında Manisa ilinde iki yaş üstü nüfusta hepatit A seronegatifliğinin sosyal belirleyicilerle ilişkisinin incelenmesi amaçlanmıştır. Yöntem: Araştırmanın bağımlı değişkeni, hepatit A seronegat...