Hot Water Recirculation and Control, a Solution to Reduce Energy Consumption
Journal Title: Analele Universitatii "Eftimie Murgu" Resita. Fascicula de Inginerie - Year 2015, Vol 22, Issue 1
Abstract
For the energy consumption reduction in the buildings sector, EU pro-poses guidelines regarding energy performance. EU Member States must take measures to ensure the conversion of buildings into nearly zero energy buildings, which should also include measures to optimize installations for domestic hot water (DHW). From this point of view the present paper deals with issues regarding hot water recirculation and control aiming to reduce fuel consumption necessary for DHW preparation. To this end the benefits of DHW preparation process optimization were analyzed, in order to ensure a theoretical constant temperature having values in a narrow domain and an efficient thermal fluid distribution in the network for better controlling hot water temperature.
Authors and Affiliations
Adriana Tokar, Arina Negoițescu
Influence at Work Distance between the Sonotrode and Specimen to Cavitational Erosion
The paper presents the results of cavitation erosion tests performed on five samples from pure aluminum using the vibratory method with stationary specimen. The main purpose of this research is for deter-mine which is...
Exploitation Solution of the Wind Potential in the Danube Gorge
This paper proposes a solution to exploit the wind potential of the Danube cluster by storing it in the Iron Gates I reservoir lake, through pumping the water downstream of the hydroelectric power plant. Storing energy b...
Monitoring System Dynamic Regimes with VariableReluctance Synchronous Motors
This paper will present an overview of how can we use a data acquisition (DAQ) device to quickly and easily acquire and present the data of dynamic regimes of variable reluctance synchronous motors. The described monitor...
Attenuation of Road Traffic Noise by Vegetation in Urban Spaces
The last decades of the 20th century and the beginning of the 21st century have been characterized by rapid urban growth of cities, which resulted in overcrowding and the lack of land. The aftermath of such circumstances...
Sinc Function based Interpolation Method to Accurate Evaluate the Natural Frequencies
Due to leakage phenomena the frequencies and amplitude of the vibration signals given by the sinc function are not indicated correctly. There are interpolation methods that solve the problem of frequency evaluation but w...