HVDC TRANSMISSION LINE PROTECTION BASED ON TRANSIENT ENERGY AND TRANSIENT POWER: A SURVEY

Abstract

As the number of consumers of electricity increases the electric power generated required to serve the consumers increases. Due to the long distance transmission of the generated power the power system becomes complex. That is why HVDC transmission system used for long distance carriage of power. During transmission of HVDC system protection and security of the system is compulsory in order to minimize the overall losses. This review paper discusses the protection of HVDC line based on transient energy and transient power. The fault which is occurred on the system reflected on three main parts of the system. Using modified traveling wave algorithm the transient parameters are determined and the type and location of fault can be detected. The simulation is done using PSCAD/EMTDC, MATLAB/Simulink. Motivation/Background: Due to the complication of a power system, HVDC power transmission system was chosen. But the system needs protection to secure the transportation of the needed amount of power. Method: In this review paper a modified travelling wave algorithm is used to detect the faults. Results: The result from the output of the algorithm shows the transient power and energy came to stability within short time. Conclusions: By detecting the transient power and energy, it can easily be protect the system from severe problem.

Authors and Affiliations

Keywords

Related Articles

STUDY AND ANALYSIS OF CONSUMER BUYING BEHAVIOR IN RETAIL MARKET

The aim of this study are determining the impact of the most used tools of sales promotion in retail sector such as coupons, sample, price discount and buy one get one free on consumer buying behavior from two aspects ar...

VERIFICATION OF CARRY LOOK AHEAD ADDER USING CONSTRAINED RANDOMIZED LAYERED TEST BENCH

In processors and in digital circuit designs, adder is an important component. As a result, adder is the main area of research in VLSI system design for improving the performance of a digital system. The performance depe...

ALGAE AS BIOINDICATORFOR POLLUTION OF TIGRIS RIVER BY INDUSTRIAL WASTE

This study has been conducted during 2016, the samples were collected from discharge of General Company for Vegetable Oil Industry before and after treatment in Baghdad city. Some parameters were measured such as: Temper...

COMPRESSION DAMAGE THRESHOLD OF YOUNG COCONUT (Cocos nucifera L.) AT TWO MATURITY STAGES

Information on the damage incidence of young coconut was generated by establishing the threshold values due to compression. Factors influencing damage and deformation under dead load were evaluated. It was found that mat...

SALIENT AREA DISCERNMENT VIA HIGH DIMENSIONAL COLOR TRANSFORM AND LOCAL SPECIAL PLATFORM

Detecting visually salient regions in images is fundamental problems and it is useful for applications like image segmentation, adaptive compression, and object recognition. A salient object region is a soft decompositio...

Download PDF file
  • EP ID EP282956
  • DOI 10.5281/zenodo.1206022
  • Views 112
  • Downloads 0

How To Cite

(2018). HVDC TRANSMISSION LINE PROTECTION BASED ON TRANSIENT ENERGY AND TRANSIENT POWER: A SURVEY. INTERNATIONAL JOURNAL OF ENGINEERING TECHNOLOGIES AND MANAGEMENT RESEARCH, 5(3), 21-32. https://europub.co.uk/articles/-A-282956