Hysteresis Current Control Based Shunt Active Power Filter for Six Pulse Ac/Dc Converter

Abstract

In this paper the simulation of Shunt Active power Filter using P-Q theory and PI controller has been presented. This SAPF compensates the harmonic currents drawn by three phase six pulse AC/DC converter. The process of compensation is done by calculating the instantaneous reactive power losses using p-q theory and the PI controller to reduce the ripple voltage of the dc capacitor of the PWM-VSI. This approach is different from conventional approach and provides very effective solution. In this simulation we use hysteresis band current controller (HCC) for switching the VSI inverter. The simulation has been done for both steady state and transient conditions.

Authors and Affiliations

Rakesh Kumar Pandey, Vaibhav Purwar, Nikhlesh Sharma

Keywords

Related Articles

Mobile Government: Kuwait Ascase Study

The advances in Information and Communication Technology (ICT) have a great impact on our lifestyle. The improvement of tablet PC’s, mobile phones, PDAs and the smart phone connected people any time anywhere. The private...

GPU Implementation over IPTV Software Defined Networking

One of the most important issue in IPTV Software defined Network is Bandwidth Issue and Quality of Service at the client side. Decidedly, it is required high level quality of images in low bandwidth and for this reason i...

Optimal Placement of Dynamic Voltage Restorer in Distribution Systems for Voltage Improvement Using Particle Swarm Optimization

This paper deals with Dynamic Voltage Restorer (DVR) allocation in radial distribution systems by injecting series voltage. The DVR is used to inject both real and reactive powers into the system for voltage profile impr...

Optimization of Voltage, Delay, Power and Area for 16 bit Cyclic Redundancy Check (CRC) in VLSI Circuits using 45nm Technology

In Very-large-scale integration (VLSI) application area, delay and power are the important factors for any digital circuits. This paper presents 16 bit Cyclic Redundancy Check (CRC) mapped in Cadence Encounter(R) RTL Com...

Synthesis, characterization of Banana / Glass Fiber Reinforced Epoxy Based Hybrid Composites

Natural fiber composites are nowadays being used in various engineering applications to increase the strength and optimize the weight and the cost of the product. Hybridization is a process of incorporating synthetic fib...

Download PDF file
  • EP ID EP389963
  • DOI 10.9790/9622- 0702012630.
  • Views 164
  • Downloads 0

How To Cite

Rakesh Kumar Pandey, Vaibhav Purwar, Nikhlesh Sharma (2017). Hysteresis Current Control Based Shunt Active Power Filter for Six Pulse Ac/Dc Converter. International Journal of engineering Research and Applications, 7(2), 26-30. https://europub.co.uk/articles/-A-389963