I Gel Versus Endotracheal Tube for Pediatric day Care Surgeries
Journal Title: Indian Journal of Anesthesia and Analgesia - Year 2019, Vol 6, Issue 1
Abstract
Background: The I-gel TM (Intersurgical, Wokingham, UK) is a novel second generation supraglottic airway device with a non inflatable cuff, made up of a unique soft gel like material (Styrene Ethylene Butadiene Styrene). The device is transparent and latex free. It is easy to insert and has minimal tissue compression. An integrated gastricchannel is provided for passage of gastric drainage tube to empty the stomach. Objectives: The aim of the present study wasto compare the efficacy of I-gel with Endotracheal tube in airway management in children. Materials and methods: This study was conducted at tertiary referral centre for new born and children with Children of age 2 to 6 years, weighing 10 to 18 kg, ASA Grade I-II posted for elective day care procedures. Results: Males were predominant in both the groups. Insertion and ease of placement was successful in first attempt in 86.66% of patients in Group I as compared to 80% in Group II (ET). 13.33% of patients in Group I (3 out of 30) required adjustment like jaw thrust, neck extension or reinsertion because of forward displacement. One patient had been recorded in Group I (I- gel) as failure because of inadequate ventilation and required endotracheal intubation. 20% in Group II required second attempt for ET tube placement because of early learning curve of anaesthesia trainees in the teaching institute. There was a significant rise in HR & BP in Group II during laryngoscopy and intubation and at the time of extubation. Airway related adverse events (coughing, breathholding, laryngospasm) were more in Group II when compared to Group I. Conclusion: The I-gel is ease of insertion, success rates, minimal hemodynamic perturbations and minimum perioperative adverse effects.
Authors and Affiliations
Sunil kumar
Effect of Positioning after Induction of Spinal Anaesthesia with 0.5% Hyperbaric Bupivacaine in Orthopedic Procedures
Context: Spinal anesthesia is considered safe over general anesthesia but has some side effects. To overcome its side effects, it can be given in sitting position and after two minutes patient can be kept in supine posit...
Assessment of Airway Changes in Pregnant Women at Onset of Labour, Following Delivery and after 48 Hrs
Introduction /Context: High incidence of difficult or failed intubation in pregnant patients is still a major challenge for anaesthesiologists. To evaluate airway changes in pregnant patients we used mallampatti grade an...
Comparision of Intubating Conditions at 60 Seconds with Different Doses of Rocuronium Using the Train of Four Monitoring
Objective: To evaluate the intubating conditions with rocuronium at 0.6mg/kg (2*ED95) and 0.9mg/kg (3*ED95) at 60 seconds using the timing principle. Methods: 60 patients were divided into 2 groups of 30 each. Group A re...
Preventive Analgesic Efficacy of Intravenous Tramadol Versus Intravenous Nalbuphine for Elective Inguinal Hernia Repair Surgeries :Randomised Controlled Trial
Background Information: One of the challenges in postoperative care in a developing country is the non-availability of narcotics. Morphine and fentanyl have excellent analgesic action but they are difficult procure as th...
Effects of Intravenous Ondansetron and Granisetron on Hemodynamic Changes and Blockade Characterestics Induced By Spinal Anesthesia: A Prospective Observational Study
Background: Spinal anaesthesia has many advantages for elective surgeries, but the undesired effect of hypotension is to be managed by different interventions. Induction of the Bezold Jarisch reflex in the setting of d...