I-STAT, COAGUCHEK XS PLUS, AND HEMOCHRON VERSUS REFERENCE LABORATORY INRS: PHARMACIST-MANAGED CLINICS

Abstract

Objectives: The international normalized ratio (INR) is the primary measure used to determine the therapeutic effect of warfarin. I-Stat, CoaguChek-XS Plus, and Hemochron are the most frequently used point-of-care tests (POCTs); hence, we compared the results of each with our reference laboratory results.Methods: Subjects were recruited during our clinic’s annual evaluation phase for therapeutic optimization. Upon acceptance, an instant finger-stick or finger-prick test was performed as required in addition to venous blood sampling. Approximately 0.1–0.3 mL of blood was taken peripherally for the POCTs, whereas 3 mL was taken for the reference laboratory to measure the INR. Bland-Altman plots were used to analyze the data and test their agreement.Results: A total of 180 blood samples were taken from 45 patients. The sample volumes for Hemochron were higher than for I-Stat and CoaguChek-XS Plus, and 70% of patients reported more pain for this method. While I-Stat has additional test options and does not require a finger stick, CoaguChek-XS Plus is the cheapest test in terms of the acquisition cost for the handset and strips. The INR estimated by the reference laboratory ranged from 1.1 to 8. The Bland-Altman plots revealed a good agreement between methods, with only 3–6 outliers in each plot. Of the samples, 6%, 6%, and 13% of the results were considered to be outside the clinically acceptable range (±0.5 INR) for I-Stat, CoaguChek-XS Plus, and Hemochron, respectively.Conclusion: The results obtained using the three POCTs are in good agreement with the reference laboratory results. 

Authors and Affiliations

Ahmad Abdulrahman Almeman

Keywords

Related Articles

A STUDY ON EFFECT OF INDOLE AS A SUBSTITUENT ON A KETO-ENOL TAUTOMER: A SYNTHETIC APPROACH ON β-DIKETONE

Objective: The existence of keto-enol tautomerism in β-diketones can typically study by a choice of analytical technique. The position of the keto-enol equilibrium depends on a number of factors like solvent, temperatur...

ASSESSMENT OF KIDNEY FUNCTION, ESTIMATED GLOMERULAR FILTRATION RATE AND BODY MASS INDEX IN HIV SEROPOSITIVE SUBJECTS ON ANTIRETROVIRAL THERAPY IN NNEWI

Objective: Antiretroviral therapy (ART) is anticipated to result in an increase in long-term survival in human immunodeficiency virus (HIV) infected individuals, but may present with the development of associated complic...

DOSE-DEPENDENT AMELIORATION OF EPIGALLOCATECHIN-3-GALLATE AGAINST SODIUM VALPROATE INDUCED AUTISTIC RATS

Objective: Autism is a neurodevelopment related disorder with a range of clinical presentations attending serious behavioral and neurological disorders among young children that now occur at epidemic rates in developing...

A STATISTICAL APPROACH BASED ON THE TOTAL ERROR CONCEPT FOR VALIDATION THE BIOANALYTICAL METHOD: APPLICATION TO THE SPECTROPHOTOMETRIC DETERMINATION OF TRACES AMOUNT OF ACETAMINOPHEN IN HUMAN PLASMA

Objective: The use of the classical approach of analytical validation, in practice or in the literature, is common. However, statistical verification, that looks separately the two errors (such as bias and precision) to...

NOVEL SMART pH SENSITIVE CHITOSAN GRAFTED ALGINATE HYDROGEL MICROCAPSULES FOR ORAL PROTEIN DELIVERY: I. PREPARATION AND CHARACTERIZATION

Objectives: Preparation and characterization of a new pH sensitive chitosan (CS) grafted alginate (ALG) hydrogel microcapsules for the oral delivery of protein.Methods: The pH sensitive hydrogel microcapsules were prepar...

Download PDF file
  • EP ID EP579205
  • DOI -
  • Views 66
  • Downloads 0

How To Cite

Ahmad Abdulrahman Almeman (2015). I-STAT, COAGUCHEK XS PLUS, AND HEMOCHRON VERSUS REFERENCE LABORATORY INRS: PHARMACIST-MANAGED CLINICS. International Journal of Pharmacy and Pharmaceutical Sciences, 7(1), 284-288. https://europub.co.uk/articles/-A-579205