Abstract

Background: Cardiac MRI examination is relatively rare in Indonesia. The effect of the use of volume shim on moving organs, such as the heart is relatively unknown and noticed by radiographers and cardiologists. Objective: To analyse the image quality of 4 chamber sections of Cardiac Magnetic Resonance Imaging with and without the use of shim volume on Steady State Free Precession (SSFP) sequences so that it can determine the most optimum 4 chamber images to maintain the diagnostic value by physician. Method: This research is designed through quantitative analytic approach with experiment method. The total samples used are 13 subjects ranging from 7 to 80 years old and 5 respondents and the sample undergone into a series of examinations of Cardiac Magnetic Resonance Imaging. Afterward, the 4 chamber sections in SSFP sequence were given different treatment, namely, with and without the use of shim volume. The result will be assessed by the respondents and then it will be done by non-parametric Wilcoxon Two-Sample Test and parametric Paired Sample T Test. Results: Thereafter, the result of statistic from the respondent assessment is that the quality of anatomy images has p=(0.113) whereas the p=(0.354) for the degree of artefact images and clarifies that the anatomy image quality and the degree of artefact is not too much different. Conclusion: The conclusion of the research is with and without the use of shim volume is not too significant to affect the quality of 4 chamber images.

Authors and Affiliations

Clinton Johan Ade Wicaksono, Susy Suswaty, Nursama Heru Apriantoro, Ary Sasongko

Keywords

Related Articles

ANALYSIS OF FRACTIONAL ANISOTROPY (FA) VALUES AND APPARENT DIFFUSION COEFFICIENT (ADC) VALUES IN ISCHEMIC STROKE DISEASES OF MRI GE 3 TESLA

Background: Diffusion Weighted Imaging and Diffusion Tensor Imaging is an advanced technique in MRI that shows the diffusion in brain of ischemic stroke disease. Diffusion Weighted Imaging (DWI) shows the lesions without...

RISK ASSESSMENT OF OVERHEAD CRANE (OHC) DOUBLE GIRDER OPERATION IN THE KAPAL NIAGA DIVISION IN PT PAL INDONESIA (PERSERO)

Background: PT PAL Indonesia (Persero) operates Overhead Crane Double Girder tool everyday. The operation of the device have some risk of material hazard, material pinched, material scratched, fracture and passed away. P...

DETERMINATION OF LOCAL DIAGNOSTIC REFERENCE LEVEL (LDL) PEDIATRIC PATIENTS ON CT HEAD EXAMINATION BASED ON SIZE-SPECIFIC DOSE ESTIMATES (SSDE) VALUES

Background: CT Scan provides the biggest contribution in receiving radiation doses in patients. Especially in pediatric patients or children. Local DRL (Diagnostic Reference Level) is an effort to optimize radiation for...

COMPARISON BETWEEN REMOVABLE AND FIXED ORTHODONTIC RETAINERS

Background: There are two kinds of retainers: removable retainer and fixed retainer. Removable retainer is an orthodontic retainer which can be inserted and removed by the patient, whereas fixed retainer is bonded perman...

FABRICATION TECHNIQUE OF DENTAL RESTORATION USING HYBRID CERAMIC WITH CAD CAM METHOD

Background : Ceramic is superior in aesthetic but fragile and breakable under bite pressure . Lack of understanding of material requirements for resistance in the oral cavity and minimal ceramic processing techniques is...

Download PDF file
  • EP ID EP594266
  • DOI 10.20473/jvhs.V1.I3.2018.97-101
  • Views 211
  • Downloads 0

How To Cite

Clinton Johan Ade Wicaksono, Susy Suswaty, Nursama Heru Apriantoro, Ary Sasongko (2018). IMAGE QUALITY ANALYSIS 4 CHAMBER SECTIONS OF CARDIAC MRI WITH AND WITHOUT UTILIZING SHIM VOLUME IN THE STEADY STATE FREE PRECESSION SEQUENCES. Journal of Vocational Health Studies, 1(3), 97-101. https://europub.co.uk/articles/-A-594266