IMAGE QUALITY ANALYSIS 4 CHAMBER SECTIONS OF CARDIAC MRI WITH AND WITHOUT UTILIZING SHIM VOLUME IN THE STEADY STATE FREE PRECESSION SEQUENCES

Journal Title: Journal of Vocational Health Studies - Year 2018, Vol 1, Issue 3

Abstract

Background: Cardiac MRI examination is relatively rare in Indonesia. The effect of the use of volume shim on moving organs, such as the heart is relatively unknown and noticed by radiographers and cardiologists. Objective: To analyse the image quality of 4 chamber sections of Cardiac Magnetic Resonance Imaging with and without the use of shim volume on Steady State Free Precession (SSFP) sequences so that it can determine the most optimum 4 chamber images to maintain the diagnostic value by physician. Method: This research is designed through quantitative analytic approach with experiment method. The total samples used are 13 subjects ranging from 7 to 80 years old and 5 respondents and the sample undergone into a series of examinations of Cardiac Magnetic Resonance Imaging. Afterward, the 4 chamber sections in SSFP sequence were given different treatment, namely, with and without the use of shim volume. The result will be assessed by the respondents and then it will be done by non-parametric Wilcoxon Two-Sample Test and parametric Paired Sample T Test. Results: Thereafter, the result of statistic from the respondent assessment is that the quality of anatomy images has p=(0.113) whereas the p=(0.354) for the degree of artefact images and clarifies that the anatomy image quality and the degree of artefact is not too much different. Conclusion: The conclusion of the research is with and without the use of shim volume is not too significant to affect the quality of 4 chamber images.

Authors and Affiliations

Clinton Johan Ade Wicaksono, Susy Suswaty, Nursama Heru Apriantoro, Ary Sasongko

Keywords

Related Articles

DETERMINATION OF LOCAL DIAGNOSTIC REFERENCE LEVEL (LDL) PEDIATRIC PATIENTS ON CT HEAD EXAMINATION BASED ON SIZE-SPECIFIC DOSE ESTIMATES (SSDE) VALUES

Background: CT Scan provides the biggest contribution in receiving radiation doses in patients. Especially in pediatric patients or children. Local DRL (Diagnostic Reference Level) is an effort to optimize radiation for...

ALLERGIC RHINITICAL THERAPY WITH ACUPUNCTURE, LEGUNDI AND TEMULAWAK HERBS

Background: Allergic rhinitis is an inflammatory disease of the nasal mucosa mediated by IgE (immunoglobulin E) with the main mediator histamine. Rhinitis in the science of Traditional Chinese Medicine (TCM) is called Bi...

ACUPRESSURE AND AROMATIC GINGER HERB FOR A MIGRAINE

Background: a Migraine is a headache with pain attacks lasting 4 - 72 hours. Pain is usually unilateral, it is pulsating, the intensity of pain is moderate to severe and aggravated by activity, and can be accompanied by...

FACTORS RELATED TO UNSAFE BEHAVIOR OF PILE WORK AT PT WASKITA KARYA (PERSERO) HIGHWAY PROJECT KLBM SECTION 2 WADUK BUNDER AREA

Background: Occupational accidents are generally caused by 2 main points of unsafe action and unsafe condition. Several previous studies have shown that unsafe behavior significantly affects the onset of occupational acc...

SCORING ANALYSIS OF THE RELATIONSHIP BETWEEN MAGNETIC RESONANCE IMAGING- ANXIETY QUESTIONNAIRE (MRI-AQ) WITH HEART RATE TO PATIENTS ANXIETY LEVEL AT LUMBOSACRAL MRI EXAMINATION

Background: Anxiety during MRI examination becomes a common constraint and can have a negative effect that is the quality of the resulting image due to the existence of motion artifacts until the failure of the examinati...

Download PDF file
  • EP ID EP594266
  • DOI 10.20473/jvhs.V1.I3.2018.97-101
  • Views 213
  • Downloads 0

How To Cite

Clinton Johan Ade Wicaksono, Susy Suswaty, Nursama Heru Apriantoro, Ary Sasongko (2018). IMAGE QUALITY ANALYSIS 4 CHAMBER SECTIONS OF CARDIAC MRI WITH AND WITHOUT UTILIZING SHIM VOLUME IN THE STEADY STATE FREE PRECESSION SEQUENCES. Journal of Vocational Health Studies, 1(3), 97-101. https://europub.co.uk/articles/-A-594266