Implantation of permanent pacemakers in Cuenca–Ecuador, from 2017 to 2018

Journal Title: Wearable Technology - Year 2020, Vol 1, Issue 2

Abstract

Introduction: In recent years, the placement frequency of permanent pacemakers has increased due to some risk factors, some of which are carried out through cables. Objective: To determine the prevalence and related factors of permanent pacemaker implantation in adult patients in the cardiology department of José Calasco Artega hospital in 2017. Methods: a randomized cross–sectional study was conducted on 422 patients over 18 years old in the cardiology department of “José Carrasco Arteaga” hospital in Cuenca, Ecuador from January to December 2017. Information is processed in SPSS software version 24. Descriptive statistical analysis based on frequency and percentage was used to measure the statistical correlation with odds ratio (or) within 95% confidence interval. When p<0.05, it was considered to be statistically significant. Results: The implantation rate of cardiac pacemaker was 7.1%, and the average age was 65.52 years (DS±14.77), mainly male. The risk factors associated with pacemaker implantation were atrioventricular block or 42.56 (95% confidence interval: 16.06–112.73, p=0.000); Sinoatrial node disease or 59.34 (95% CI: 11.67–301.93, P=0.000) and others or 0.017 (95% confidence interval: 0.00–0.05, p=0.000). Atrial fibrillation was not statistically significant or 1.71 (95% confidence interval: 0.62–4.71, p=0.354). Conclusion: The prevalence of pacemaker implantation is 7.1%, which is related to atrioventricular block, which is the main risk factor, followed by nodular diseases.

Authors and Affiliations

Brigitte Estefanía Secaira Neira, Hermel Medardo Espinosa Espinosa, Lizette Espinosa Martin, Zoila Katherine Salazar Torres, Karla Alexandra Aspiazu Hinostroza, Juan José Solano Noblecilla

Keywords

Related Articles

Research progress of fabric electrodes in wearable electronic clothing

Aiming at the application requirements of fabric electrodes in wearable electronic clothing, the current materials and structure types of fabric electrodes are introduced respectively, the influence of fabric electrodes...

Application of embedded accident prevention system for infant crawling stage in intelligent textiles

Infant crawling is a method to discover and learn its motor, cognitive, social and emotional functions. Therefore, infants face different risks, such as falls, burns and personal injuries. The most common is that the fam...

Design of a wearable upper limb rehabilitation robot and its motion simulation and dynamics analysis

Objective: A new wearable upper limb rehabilitation robot is designed to address the disadvantages of the current desktop upper limb rehabilitation robot, which is bulky and inconvenient to move, and the rationality of t...

Research progress on wearable devices for daily human health management

As the public’s demand for portable access to personal health information continues to expand, wearable devices are not only widely used in clinical practice, but also gradually applied to the daily health management of...

Deep learning-based discriminant model for wearable sensing gait pattern

In order to effectively improve the accuracy of identifying the gait pattern of wearable sensing data, this paper proposes a new model for deep learning gait mode discrimination that integrates convolutional neural netw...

Download PDF file
  • EP ID EP709928
  • DOI 10.54517/wt.v1i2.1657
  • Views 91
  • Downloads 0

How To Cite

Brigitte Estefanía Secaira Neira, Hermel Medardo Espinosa Espinosa, Lizette Espinosa Martin, Zoila Katherine Salazar Torres, Karla Alexandra Aspiazu Hinostroza, Juan José Solano Noblecilla (2020). Implantation of permanent pacemakers in Cuenca–Ecuador, from 2017 to 2018. Wearable Technology, 1(2), -. https://europub.co.uk/articles/-A-709928