Implantation of trabecular micro-bypass stent using a novel “landing strip” technique

Journal Title: International Journal of Ophthalmology - Year 2017, Vol 10, Issue 5

Abstract

"AIM: To describe a novel technique of creating a landing strip within the trabecular meshwork to guide trabecular micro-bypass stent (iStent) implantation in patients who underwent phacoemulsification. METHODS: Thirty-four eyes from 30 patients who underwent iStent implantation after phacoemulsification from May 2014 to February 2015 were included in our retrospective study. All iStents were implanted via the “landing strip” technique. A 25-gauge microvitreoretinal blade was used to bisect the trabecular meshwork to less than 1 clock-hour, effectively creating a landing strip. The iStent applicator was pressed along the landing strip and then the stent was released into the trabecular meshwork. RESULTS: Of the 34 eyes with iStent implantation, 27 (79.4%) eyes had primary open-angle glaucoma, 6 (17.6%) eyes had pseudoexfoliation glaucoma, and 1 (2.9%) eye had ocular hypertension. At 6-month follow-up (n=17), the mean number of hypotensive medications decreased from 2.2±1.2 at baseline to 0.8±1.3 (P=0.05) and mean intraocular pressure decreased from 19.7±4.1 mm Hg at baseline to 16.7±2.1 mm Hg (P=0.58). Two eyes (5.9%) required subsequent trabeculectomy. CONCLUSION: The “landing strip” technique appears to be an effective way to assist with iStent implantation."

Authors and Affiliations

Michael Waisbourd

Keywords

Related Articles

Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults

This study aims to evaluate the clinical results of posterior chamber implantable collamer lens (ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24y (range 19.2 to 42....

Intraocular lens optic capture in pediatric cataract surgery

Posterior capsule opacification (PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended cons...

Foveal thickness reduction after anti-vascular endothelial growth factor treatment in chronic diabetic macular edema

"AIM: To report foveal thickness reduction in eyes with resolution of macular edema and recovery of a foveal depression after one-year of anti-vascular endothelial growth factor (anti-VEGF) therapy for center-involving d...

Modified ulcer debridement in the treatment of the superficial fungal infection of the cornea

"AIM: To evaluate the efficacy of modified corneal ulcer debridement in superficial fungal keratitis unresponsive to medications. METHODS: A total of 209 patients (209 eyes) with fungal keratitis, involving no more than...

Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia

This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements we...

Download PDF file
  • EP ID EP603460
  • DOI 10.18240/ijo.2017.05.13
  • Views 45
  • Downloads 0

How To Cite

Michael Waisbourd (2017). Implantation of trabecular micro-bypass stent using a novel “landing strip” technique. International Journal of Ophthalmology, 10(5), -. https://europub.co.uk/articles/-A-603460