Abstract

The safe operation of a hydro generator depends on its thermal regime, the basic conditions being that the temperature in the stator winding fall within the limits of the insulation class. As the losses in copper depend on the square current in the stator winding, it is necessary that the cooling water debit should be adapted to the values of these losses, so that the winding temperature falls within the range of the values prescribed in the specifications. This paper presents an efficient solution of commanding and monitoring the water cooling installations of two high-power hydro generators.

Authors and Affiliations

Ioan Pădureanu, Marcel Jurcu, Ladislau Augustinov, Cornel Hațiegan, Eugen Răduca

Keywords

Related Articles

Pre-processing of Images as a Source of Additional Information for Image of the Natural Polymer Composites

Image processing is one of the methods of analyzing and obtaining new information. Image processing methods can be applied to any im-age. Image processing is used in various fields of research. Among the stages of image...

Sensitivity Modeling and Evaluation of Evapo-transpiration Effects on Flow Discharge of River Owena in Nigeria

Analysis of discharges, precipitation and temperature and some other meteorological-hydrological variables from 1996-2011 at the section of Owena River Basin. The evaluation, correlations, and the relationship between pr...

Estimation of Reference Melon Crop-Evapo-transpiration using Eto[Pan-Fao/Penman] and Cropwat Models

Aiming at contributing to an adequate management of water resources, accurate estimation of reference evapotranspiration (ETo) using evapo-ration pan, FAO-Penman and CROPWAT model is very important for the computation of...

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

This paper provides a theoretical comparison of the performance of refrigerants in use in a vapor comparison cycle. It is about the phase-out of R134a from actual refrigeration system, comparison being performed for this...

Automatic Control of a Dual-SMA Actuator System

The present paper describes research results considering the automatic control of a prehension module using a dual shape memory alloy (SMA) actuator. The offspring targeted a high-speed prehension appliance by means of...

Download PDF file
  • EP ID EP449040
  • DOI -
  • Views 78
  • Downloads 0

How To Cite

Ioan Pădureanu, Marcel Jurcu, Ladislau Augustinov, Cornel Hațiegan, Eugen Răduca (2015). Implementation of an Automatic System for the Monitoring of Start-up and Operating Regimes of the Cooling Water Installations of a Hydro Generator. Analele Universitatii "Eftimie Murgu" Resita. Fascicula de Inginerie, 22(1), 359-368. https://europub.co.uk/articles/-A-449040