Implementation of Cascaded H Bridge Control Scheme for SSSC using Zero Sequence Voltage and Negative Sequence Current

Abstract

This paper focuses on a control scheme of cascaded H bridge scheme implemented in SSSC for enhance the three phase power systems. Cascaded H bridge based SSSC has offer low switching losses and less total harmonics distortion, and reduces the number of circuit components. Each H bridge cell has isolated dc capacitors which is exist balanced capacitor voltages. Since SSSC is often requested to operate under asymmetrical condition by power system faults such as one line grounding or two line short circuit and it can be the control output current almost freely. Cascaded H bridge based SSSC needs wide range of margin of dc voltage for operates in large unbalanced voltage power system. This proposed system focused on to avoids wide range of margin of dc voltage by exclusively using the two methods such has zero sequence voltage and negative sequence current. By this scheme, the SSSC is allowed to operate under asymmetrical condition by power system faults. The validity is examined by digital simulation under one line and two line fault in power system. M. Subalakshmi | A. Rathinam ""Implementation of Cascaded H-Bridge Control Scheme for SSSC using Zero Sequence Voltage and Negative Sequence Current"" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-2 , February 2020, URL: https://www.ijtsrd.com/papers/ijtsrd30063.pdf Paper Url : https://www.ijtsrd.com/engineering/electrical-engineering/30063/implementation-of-cascaded-h-bridge-control-scheme-for-sssc-using-zero-sequence-voltage-and-negative-sequence-current/m-subalakshmi

Authors and Affiliations

M. Subalakshmi | A. Rathinam

Keywords

Related Articles

A Brief Overview on Active Air Sampling Procedure for Environment Monitoring

In this paper, we are going to discuss the ‘Active Air Sampling procedure for EM'. EM stands for Environment Monitoring. Environment monitoring is performed in the pharmaceutical manufacturing plants to monitor the con...

Role of Women Cooperative in Agricultural Development: (A Study of Women Cooperative Members in Awka South)

This paper dwelt on the role of women cooperative in agricultural development focusing on Awka south local government area of Anambra state. Sixty-five (65) farmer members were randomly selected from six women cooperativ...

Effect of Compaction Moisture Content on Strength Parameters of Unsaturated Clay using Triaxial Test

Soil compaction is a process of mechanical densification of soil by pressing the soil particles close to each other and removing the air between them. It is of utmost importance in the broad science of Geotechnical engin...

Impact of Self Defence Technique Training on Practice of Adolescent Girls

The present study has been conducted to know the impact of self defence technique training on practice of adolescent girls. Inorder to achieve the objectives one group pretest post test preexperimental research design wi...

Seismic Analysis of Framed R.C. Structure with Base Isolation Technique using E Tabs

A Natural Calamity like an earthquake has taken a million lives throughout in our past. The force induced due to earthquake is dangerous and last for short duration of time. There are various techniques that can be used...

Download PDF file
  • EP ID EP685968
  • DOI -
  • Views 104
  • Downloads 0

How To Cite

M. Subalakshmi (2020). Implementation of Cascaded H Bridge Control Scheme for SSSC using Zero Sequence Voltage and Negative Sequence Current. International Journal of Trend in Scientific Research and Development, 4(2), -. https://europub.co.uk/articles/-A-685968