Improved Direct Power Control for Brushless Doubly-Fed Wind Power Generator Under Unbalanced Grid Voltage Conditions

Abstract

Thepaper presents the complete modeling and control strategy of variable speed wind turbine system (WTS) driven brushless doubly fed induction generators (BDFIG). A back-to-back converter is employed for the power conversion exchanged between BDFIG and grid.The wind turbine is operated on the maximum power point tracking (MPPT) mode its maximum efficiency. Direct power control (DPC) based on selecting of the appropriate CW stator voltage vectors and the errors of the active and reactive power, the control strategy of CW stator side converter (MSC) combines the technique of MPPT and direct power control. In the control system of the grid side converter (GSC) the direct power control based an improved switching table (IST-DPC) with notch filter has been used tomaintain a constant DC-Link voltage and the reactive power is set to zero and better current quality compared with the conventional switching table .in addition, the behaviors of BDFIG under unbalanced grid voltage conditions are studied and a power compensation scheme is developed to improve the power quality. Simulations results using MATLAB/SIMULINK are presented and discussed on a 7.5 KW BDFIG wind generation system demonstrate the effectiveness of the proposed control.

Authors and Affiliations

Abederrezak Rahab, et al.

Keywords

Related Articles

Study of Mechanical Behaviour Natural Fibers Reinforced Composite Materials

In this work the investigation of experimental study of the evaluation of the different natural fiber as reinforcement with epoxy composites of mechanical properties. Composites were fabricated using Sisal/epoxy, Banana/...

Numerical and Experimental Study of Evaporation of Liquid Effluent Flowing on an Inclined Plate

This work deals with the recovery of liquid effluent by thermal evaporation. The effluent is a digestate of pig manure which is subjected to anaerobic digestion and phase separation by centrifugation. Its dry matter is a...

Loadability Analysis of the Effect of Generation and Transmission Expansion in Southern Nigeria

Electrical energy demand in Nigeria has increased due to economic activities as a result of increase in population. The Southern region, experience stranded power due to the proximity of most of the gas thermal power sta...

Secured Key Menagement in Manufacturing Execution Systems of Cloud Connect

In manufacturing organizations, the flow of information often is essential to the functioning of critical design, processes, machinery, or systems on which the company depends. Thus, Cyber security rather than being an o...

Stability Study of LQR and Pole-Placement Genetic Algorithm Synthesized Input-Output Feedback Linearization Controllers for a Rotary Inverted Pendulum System

The rotary inverted pendulum (RIP) has a fourth order nonlinear dynamics, and its control is typically with two stages, i.e., a swing-up control and a balancing control. For Linear-quadratic regulator (LQR) control, unde...

Download PDF file
  • EP ID EP496357
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

Abederrezak Rahab, et al. (2018). Improved Direct Power Control for Brushless Doubly-Fed Wind Power Generator Under Unbalanced Grid Voltage Conditions. International Journal of Engineering Innovations and Research, 7(1), 1-8. https://europub.co.uk/articles/-A-496357