Improved first and second order control in tip edge and preadjusted edgewise appliance: KD ligation technique

Journal Title: IP Indian Journal of Orthodontics and Dentofacial Research - Year 2018, Vol 4, Issue 4

Abstract

Tip edge brackets have evolved from the edgewise brackets with the removal of the diagonally opposite corners to incorporate the features of the Beggs philosophy Consequently with the increase in the versatility of the brackets additional auxillaries were required during the finishing stage of the orthodontic treatment With different malocclusions having different requirements it strains the limit for which the brackets are designed Thus it comes to the versatility of orthodontist skills to device techniques to use the full potential of the brackets while achieving the treatment objectives in the most efficient way In the present case report we have enumerated the versatility of ligation techniques which can be used to suit the needs of the case and achieve the correction of the malocclusion in the most efficient wayKeywords Tip edge brackets Ligation technique First and Second Order control Preadjusted Edgewise Brackets

Authors and Affiliations

Shweta R Bhat, Kartik Dholakia, Aditya Talwar

Keywords

Related Articles

Improved first and second order control in tip edge and preadjusted edgewise appliance: KD ligation technique

Tip edge brackets have evolved from the edgewise brackets with the removal of the diagonally opposite corners to incorporate the features of the Beggs philosophy Consequently with the increase in the versatility of the b...

Apertognathia- A review

An anterior open bite is considered to be one of the most dentofacial deformities to treat in orthodontics The complexity of this malocclusion is attributed to a combination of skeletal dentoalveolar functional and habit...

Evaluation of morphology and position of glenoid fossa in Class I and Class II malocclusions- A cephalometric study

Aim: To analyse glenoid fossa position in Class I, II (div 1 and 2) malocclusions and to analyse variation in the shape of the glenoid fossa in different mandibular configurations. Materials and Methods: The cephalometri...

Awareness of orthodontic treatment need in young adults between 18-25 years

Introduction Health is defined by WHO as 39a state of complete physical mental and social wellbeing and not merely the absence of disease or infirmityObjectives There is a need to identify levels of awareness with respec...

The changes in shear bond strength due to repeated bonding - an in vitro study

Orthodontist face a range of problems during treatment, one commonly being bracket failure. The reason for this occurrence is usually either because of the patient’s inadvertently applying improper forces to the bracket...

Download PDF file
  • EP ID EP514553
  • DOI 10.18231/2455-6785.2018.0041
  • Views 54
  • Downloads 0

How To Cite

Shweta R Bhat, Kartik Dholakia, Aditya Talwar (2018). Improved first and second order control in tip edge and preadjusted edgewise appliance: KD ligation technique. IP Indian Journal of Orthodontics and Dentofacial Research, 4(4), 216-221. https://europub.co.uk/articles/-A-514553