IMPROVED THE ADAPTATION FOR THREE PHASE ACTIVE FILTER UNDER NON-IDEAL-LOAD USING SAMPLE CURRENT CONTROL

Abstract

In this paper, a comparison between sample current control and direct current control to show the efficiency of the two current control method of Active Power Filter. The main function of the scheme was a duty by the two-level three phases inverter. According to the classic approach, transistors are converted depending on the sign of the current error, in turn, sampled at equal intervals. Both methods follow the synchronous toggle principle. In the first method, the current vector at the end of the interval is predicted for two possible cases when the operating voltage vector towards the current fault or zero voltage vector is applied. An error generates a smaller current error at the end of the selected sampling period, thus reducing the switching frequency. In the second method, the most appropriate operating voltage vector will succeed in zero vectors over the same period. A simple algorithm is used to calculate the duty cycle to achieve the smallest possible error. Both methods are simulated with three different load modes: no load, RL load, and nonlinear load. At the end of the article, the behavior of the second method, SCC, is worth more. The simulation results demonstrate the viability and effectiveness of the two technique of current control in reducing the ripple, losses, and Total Harmonic Distortion of supply current.

Authors and Affiliations

Huynh Le Minh Thien, Nguyen Xuan Tien, Tran Thanh Vu, Ho Van Cuu

Keywords

Related Articles

STUDY ON THE BREAKDOWN OF MILLING BALLS MADE OF 13%Cr WHITE CAST-IRON WORKING IN STRONG ABRASIVE AND CLASH CONDITIONS

The breakdown due to abrasion and clash of the milling balls made of 13% Cr white cast iron is a complicated process which depends on many factors, especially on the strength of the matrix and carbide phases. As shown, s...

A STUDY ON THE FACTORS AFFECTING THE FLARE OF THE WELD WHEN WELDING THE STEEL WIRE

In this study, an equation for adjusting the parameters affecting the flare of the weld on the welding product was established. Based on the empirical research results, the factors affecting welding flux after using bend...

IMPROVED THE ADAPTATION FOR THREE PHASE ACTIVE FILTER UNDER NON-IDEAL-LOAD USING SAMPLE CURRENT CONTROL

In this paper, a comparison between sample current control and direct current control to show the efficiency of the two current control method of Active Power Filter. The main function of the scheme was a duty by the two...

CFD SIMULATION OF SAWDUST GASIFICATION ON OPEN TOP THROATLESS DOWNDRAFT GASIFIER

Sawdust is one of alternative energy sources to substitute the fossil fuels. The utilization of sawdust to produce energy can be done through different types of technologies. Gasification is one of techonology that can b...

AUTOMATION OF CALCULATIONS OF TECHNICAL CHARACTERISTICS OF MANOMETRIC TUBULAR SPRINGS

Tubular springs have received the name “Manometric” thanks to their initial use in manometric devices. For the wide use of tubular springs in various spheres of human activity, relevant methods of calculating their stati...

Download PDF file
  • EP ID EP572229
  • DOI 10.26480/jmerd.03.2019.76.80
  • Views 44
  • Downloads 0

How To Cite

Huynh Le Minh Thien, Nguyen Xuan Tien, Tran Thanh Vu, Ho Van Cuu (2019). IMPROVED THE ADAPTATION FOR THREE PHASE ACTIVE FILTER UNDER NON-IDEAL-LOAD USING SAMPLE CURRENT CONTROL. Journal of Mechanical Engineering Research & Developments (JMERD), 42(3), 76-80. https://europub.co.uk/articles/-A-572229