Improvements to the X-ray Spectrometer at the Aerosol Laboratory, Instituto de Física, UNAM

Abstract

Due to the demands of better (accurate and precise) analytical results using X-ray Fluorescence (XRF) at the Aerosol Laboratory, Instituto de Física, UNAM, it was necessary to carry out improvements in instrumentation and analytical procedures in the x-ray spectrometer located in this facility. A new turbomolecular vacuum system was installed, which allows reaching the working pressure in a shorter time. Characteristic x-rays are registered with a Silicon Drift Detector, or SDD, (8 mm thick Be window, 140 eV at 5.9 keV resolution), working directly in a high-vacuum, permitting the detection of x-rays with energies as low as 1 keV (Na Ka) and higher counting rates than in the past. Due to the interference produced by the Rh L x-rays emitted by the tube normally used for atmospheric and food analysis with Cl K x-rays, another tube with a W anode was mounted in the spectrometer to avoid this interference, with the possibility to select operation with any of these tubes. Examples of applications in atmospheric aerosols and other samples are presented, to demonstrate the enhanced function of the spectrometer. Other future modifications are also explained.

Authors and Affiliations

L V Mejía-Ponce , A E Hernández-López , S Reynoso-Cruces , J C Pineda , J A Mendoza-Flores , J Miranda

Keywords

Related Articles

Application of a CdTe Detector for Measurements of Mammographic X-ray Spectra

This work aims to characterize mammographic x-ray beams incident and transmitted by breast phantoms (from 0 to 45 mm) composed from known proportion of glandular and adipose tissue-equivalent materials. This study was pe...

Implementation of a Low Cost For Internal Dosimetry Radiological Survey of Ionization Radiation Exposed Workers In Nuclear Medicine Services

Because the nature of the routine activities carried on in nuclear medicine services, where several not sealed radioactive sources are used, the occupational personal exposed to ionization radiation (POE) is exposed to b...

Fusion Nuclear Data activities at FNL, IPR

this paper briefly describes the current fusion nuclear data activities at Fusion Neutronics Laboratory, Institute for Plasma Research. It consist of infrastructure development for the cross-section measurements of struc...

Effective Atomic Number Dependence of Radiological Parameters of Some Organic Compounds at 122 KeV Gamma Rays

Mass attenuation coefficient is a fundamental parameter of radiation interaction, from which the other radiological parameters like half Value Layer [HVL], tenth Value Layer [TVL], total atomic and electronic cross-secti...

Revisiting Natural Radiation in Itacaré and Guarapari Beaches

Human beings are constantly exposed to several types of natural radiation. This paper aims to study the total external dose from northwestern Brazilian beach sands. The samples were collected at Prainha in Itacaré, Bahia...

Download PDF file
  • EP ID EP596760
  • DOI 10.15415/jnp.2018.61009
  • Views 218
  • Downloads 0

How To Cite

L V Mejía-Ponce, A E Hernández-López, S Reynoso-Cruces, J C Pineda, J A Mendoza-Flores, J Miranda (2018). Improvements to the X-ray Spectrometer at the Aerosol Laboratory, Instituto de Física, UNAM. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 57-60. https://europub.co.uk/articles/-A-596760