Improvements to the X-ray Spectrometer at the Aerosol Laboratory, Instituto de Física, UNAM

Abstract

Due to the demands of better (accurate and precise) analytical results using X-ray Fluorescence (XRF) at the Aerosol Laboratory, Instituto de Física, UNAM, it was necessary to carry out improvements in instrumentation and analytical procedures in the x-ray spectrometer located in this facility. A new turbomolecular vacuum system was installed, which allows reaching the working pressure in a shorter time. Characteristic x-rays are registered with a Silicon Drift Detector, or SDD, (8 mm thick Be window, 140 eV at 5.9 keV resolution), working directly in a high-vacuum, permitting the detection of x-rays with energies as low as 1 keV (Na Ka) and higher counting rates than in the past. Due to the interference produced by the Rh L x-rays emitted by the tube normally used for atmospheric and food analysis with Cl K x-rays, another tube with a W anode was mounted in the spectrometer to avoid this interference, with the possibility to select operation with any of these tubes. Examples of applications in atmospheric aerosols and other samples are presented, to demonstrate the enhanced function of the spectrometer. Other future modifications are also explained.

Authors and Affiliations

L V Mejía-Ponce , A E Hernández-López , S Reynoso-Cruces , J C Pineda , J A Mendoza-Flores , J Miranda

Keywords

Related Articles

Elemental Analysis of Nanomaterial Using Photon-Atom Interaction Based EDXRF Technique

Presence of trace amount of foreign impurities (both metallic and non-metallic) in standard salts used for sample preparation and during the synthesis process can alter the physical and chemical behavior of the pure and...

Elemental Analysis of Soil Samples Using Thick Target-Particle Induced X-Ray Emission (TT-PIXE) Technique

In this work thick target-proton induced x-ray emission (TT-PIXE) technique has been employed for the elemental analysis of soil samples collected from Budha nullah region of Ludhiana city, Punjab. TT-PIXE analysis of sa...

Mass Attenuation Coefficient Measurements of Some Nanocarbon Allotropes: A New Hope for Better Low Cost Less-Cumbersome Radiation Shielding Over A Wide Energy Range

The mass attenuation coefficients of graphene, MWNTs and, SWNTs have been measured for gamma energy range 356 to 1332 keV from the radioactive sources 60Co, 133Ba and 137Cs using a well calibrated gamma ray spectrometer...

Fusion Nuclear Data activities at FNL, IPR

this paper briefly describes the current fusion nuclear data activities at Fusion Neutronics Laboratory, Institute for Plasma Research. It consist of infrastructure development for the cross-section measurements of struc...

Level Statistics of SU(3)↔ SU(3) Transitional Region

Level statistics oftransitional region of SU(3)↔ SU(3) interacting boson model is described with emphasis on the nearest neighbor spacing distributions. The energy levels of transitional Hamiltonian are calculated via th...

Download PDF file
  • EP ID EP596760
  • DOI 10.15415/jnp.2018.61009
  • Views 228
  • Downloads 0

How To Cite

L V Mejía-Ponce, A E Hernández-López, S Reynoso-Cruces, J C Pineda, J A Mendoza-Flores, J Miranda (2018). Improvements to the X-ray Spectrometer at the Aerosol Laboratory, Instituto de Física, UNAM. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 57-60. https://europub.co.uk/articles/-A-596760