Improving Performance of Total Harmonic Distortion Based Fault Detection Scheme for Inverter Interfaced Islanded Microgrids

Journal Title: روش های هوشمند در صنعت برق - Year 2018, Vol 9, Issue 34

Abstract

Global warming and environmental concerns have led to increasing penetration of converter interfaced renewable energy resources. One of the main challenges of inverter interfaced islanded microgrids is the fault detection. This paper investigates the performance of total harmonic distortion (THD) based fault detection scheme when various inverter topologies, main current limiting strategies, and different reference frame are employed. Then, based on this analysis, the performance of THD based fault detection scheme is improved using the instantaneous saturation limit and independent control capability in the natural reference frame. The proposed scheme does not mal-operate in the presence of non-linear loads and can distinguish fault condition from load change. Also, using the auxiliary control system, the proposed fault detection scheme is capable of detecting single line to ground fault in three wire system when synchronous/stationary reference frame is employed. Various time-domain simulations verify the effectiveness of the proposed scheme in the case of symmetrical and unsymmetrical faults.

Authors and Affiliations

Iman Sadeghkhani

Keywords

Related Articles

Upper Bound for Queue length in Regulated Burst Service Scheduling

Quality of Service (QoS) provisioning is very important in next computer/communication networks because of increasing multimedia services. Hence, very investigations are performed in this area. Scheduling algorithms effe...

A Low-Voltage and Low-Power Programmable "G" _"m" "-C" Filter for Wireless Applications

In this paper, a low voltage and low power (LV/LP) Operational Transconductance Amplifier (OTA) using FGMOS (Floating-Gate MOS) transistor is proposed. The relative tuning range of 50 is achieved in this OTA while only c...

A New ZCS high step-up converter with low auxiliary elements

In this paper, a new soft switching high step up converter is introduced which its auxiliary circuit does not have any extra switch. Therefore, it no needs extra driver circuit and control circuit is simple. Also the ene...

Control of a Linear Distillation Column Using Type-2 Fuzzy Method Optimized by Genetic Algorithm

The distillation process is important process in the chemical industry and has wide application in industry. Distillation tower is used by chemical engineers as a popular tool to separate materials and is the most common...

Classification and Feature Extraction of Electroencephalogram Signals for Epilepsy Using PCA, ICA, DWT and SVM Methods

The purpose of this article is to classify electroencephalogram signals into two types of epilepsy and healthy. To achieve the highest accuracy, various techniques have been used. The desired characteristics of these sig...

Download PDF file
  • EP ID EP569264
  • DOI -
  • Views 94
  • Downloads 0

How To Cite

Iman Sadeghkhani (2018). Improving Performance of Total Harmonic Distortion Based Fault Detection Scheme for Inverter Interfaced Islanded Microgrids. روش های هوشمند در صنعت برق, 9(34), 55-66. https://europub.co.uk/articles/-A-569264