“In vitro” wear behavior of extracoronal precision attachments

Journal Title: Stomatos - Year 2011, Vol 17, Issue 33

Abstract

The objective of this study was to evaluate the retentive ability and weight change of two extracoronal attachments after repeated insertion/removal cycles. Material and methods: Two extracoronal attachments were used, one with plastic inserts and the other one with conventional metal-alloy. Initial retentive ability was checked under a 20kgf load cell at 5mm/min. The weight of the fixed/removable pairs was verified with an electronic mass comparator. Fixed/removable pairs were tested with an insertion/removal cycling machine, for 5800 cycles (corresponding to 5 years) at a speed of 32 rpm speed. Insertion/ removal cycles were performed under artificial saliva. Weight change and retentive ability of attachments were verified at baseline, six-month, one-year, two-year, three-year, four-year and five-year time intervals. The two-way ANOVA for repeated measurements test was used to verify possible interactions between precision attachment type and retentive ability/weight change over time. Statistically significant associations were found between attachment type and retentive ability over time (P=0.006). Metal-alloy group showed significant differences between baseline and first year (P=0.005), baseline and second year (P=0.001), and between baseline and five years (P=0.035) of insertion/removal cycles. In the plastic insert group, no significant differences were found over time. No statistically significant associations were found between precision attachment types and weight change over time (P=0.643). Initial retentive ability can not be standardized for both attachments; the metal-alloy showed better performance than the plastic insert after five years. Both attachments did not show weight change after five years of simulated use.

Authors and Affiliations

Elken G. Rivaldo, Wellington Cardoso Bonachela, Paulo Henrique Orlato Rossetti, Luis C. F. Frasca

Keywords

Related Articles

Unusual foraminal position in a mandibular molar

Knowledge of possible morphological variations of the root canal system is crucial to achieve endodontic success. The radiographic apex is traditionally used as a reference point for establishing the apical limit of root...

Apical root resorption of maxillary first molars related to headgear use as detected by cone beam computed tomography

Extraoral traction (EOT) by occipital headgear is a widely used anchorage and orthopedic approach for the control of maxillary growth. The aims of this study were: 1) to test the hypothesis that headgear use may increase...

Taking new steps in dental research

Over the last 20 years, Brazilian dental research has established itself in the worldwide scenario, thanks to the quality of Brazilian investigators and teaching institutions, which have been widely supported by financin...

The role of social media in the construction of knowledge in Dentistry

This theoretical article discusses the construction of knowledge in dentistry in the context of the Network Society, bringing this theme closer to the point of view of some contemporary Social Science writers, nowadays i...

Evaluation of retentive force of attachment systems for overdentures retained by one or two implants

Objective: Single implant-retained overdentures are an appealing option for rehabilitation, but the retentive force of attachments in this setting has yet to be determined. Methods: Three attachment systems (ERA, O-Ring,...

Download PDF file
  • EP ID EP330115
  • DOI -
  • Views 80
  • Downloads 0

How To Cite

Elken G. Rivaldo, Wellington Cardoso Bonachela, Paulo Henrique Orlato Rossetti, Luis C. F. Frasca (2011). “In vitro” wear behavior of extracoronal precision attachments. Stomatos, 17(33), 51-59. https://europub.co.uk/articles/-A-330115