INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION

Journal Title: UNKNOWN - Year 2014, Vol 29, Issue 1

Abstract

In addition to other detonation parameters detonation velocity is a value that provides indirect information on the strength i.e. brisance of an explosive and explosive performance. In addition to that, detonation velocity is a value which can be measured in a relatively simpler and more precise manner, by developed and accessible methods when compared to other detonation parameters Due to its simple use, compact instruments and satisfactory accuracy, electro-optical method of detonation velocity measure¬ment is widely used. The paper describes the electro-optical measurement method and points out the factors that affect its accuracy. The accuracy of measurement is increased and measurement uncertainty is reduced by the measurement result analysis with the application of different measurement setups.

Authors and Affiliations

Mario Dobrilović, Vječislav Bohanek, Vinko Škrlec

Keywords

Related Articles

PODGRAĐIVANJE KRIŽIŠTA SMJERNOG I OTKOPNIH HODNIKA PRI PODETAŽNOM OTKOPAVANJU BOKSITA

U članku je prikazana otkopna metoda podzemne eksploatacije boksita u Rudniku boksita Posušje i dosadašnja iskustva na podgrađivanju križišta smjernih i otkopnih hodnika gdje je u oko 6% slučajeva dolazilo do loma podupi...

OPTIMALIZACIJA RASPOREDA I IZDAŠNOSTI BUNARA U POLUZATVORENOM VODONOSNOM SLOJU

Opisan je postupak primjene linearnog programiranja za optimalizaciju rada skupine bunara u poluzatvorenom vodonosnom sloju. Predviđena ograničenja u sustavu izražena su rasporedom potencijala (sniženja ) vode u bunarima...

UTJECAJ PROIZVODNJE PLINA IZ NEKONVENCIONALNIH LEŽIŠTA NA PONUDU I POTRAŽNJU ZA UKAPLJENIM PRIRODNIM PLINOM

Proizvodnja plina iz nekonvencionalnih ležišta ima dvostruku ulogu u slučaju razvoja industrije ukapljenog prirodnog plina (UPP). Razvoj tehnoloških rješenja za proizvodnju iz nekonvencionalnih izvora potencijalno utječe...

CHEMICAL AND GEOCHEMICAL CHARACTERISTICS OF THE ČEMERNICA ANTIMONITE DEPOSIT IN THE MID-BOSNIAN SCHIST MOUNTAINS

The Čemernica Sb-Zn-Hg-W quartz vein system is situated in Lower Palaeozoic metasediments formed under 3-5 kbars and 350° to 450 °C, intruded by Upper Palaeozoic rhyolites. K-Ar dating indicated three metamorphic phases....

SPRAYED CLAY TECHNOLOGY FOR THE DEEP REPOSITORY OF HIGH-LEVEL RADIOACTIVE WASTE

The sealing barrier will play very important role in the Czech disposal concept of high level radioactive waste. It follows Swedish SKB3 design where granitic rock environment will host the repository. Swelling clay base...

Download PDF file
  • EP ID EP30071
  • DOI -
  • Views 172
  • Downloads 1

How To Cite

Mario Dobrilović, Vječislav Bohanek, Vinko Škrlec (2014). INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION. UNKNOWN, 29(1), -. https://europub.co.uk/articles/-A-30071