Individual implants of a loss of palate fragments fabricated using SLM equipment

Abstract

Purpose: The aim of the article is to present the new conception of design and manufacturingindividual implants of a loss of palate fragments using Selective Laser Melting equipment.Design/methodology/approach: The designed virtual model of scaffolds have beenproduced in a process of selective laser melting (SLM). For their preparation titaniumalloy powder - Ti6Al4V of suitable granulation and shape has been used. Thus obtainedscaffolds have been observed in a scanning electron microscope. The structure of thepores is compatible with the shape of a designed unit cell. The outcarried EDS analysis hasconfirmed the chemical composition of the tested material.Findings: In the framework of research innovative porous biomimetic materials calledscaffolds with the well-defined regular structure of open pores have been used. Virtualimplant models have been made using Computer Aided Materials Design. They have thegeometrical dimensions corresponding to a fragment of a loss of a human palate. Porousand regular structure with defined geometric dimensions and shape are designed in the formof the unit cell, which has then been subjected to the multiplication process.Practical implications: The scaffolds fabricated in the SLM process create conditions fortheir application as implants of a loss of palate fragments.Originality/value: Implants for the whole palate or its part, required due to mechanicalinjuries, tumorous diseases or cleft palate are original at the basis of a literature review.

Authors and Affiliations

L. A. Dobrzański, A. Dobrzańska-Danikiewicz, T. G. Gaweł

Keywords

Related Articles

Electrospinning of PAN and composite PAN-GO nanofibres

Purpose: The aim of this study was to present the influence of used reinforcement phase – graphene oxide (GO) and the electrospinning process parameters (the distance between the nozzle and collector) on the morphology a...

The effect of colemanite addition on the properties of mullite-zirconia composites prepared by slip casting

Purpose: This study deals with the effects of colemanite (Ca2B6O115H2O) on properties ofslip-cast mullite–zirconia composites prepared via reaction–sintering of kaolinite, aluminaand zircon powders.Design/methodology/app...

Microstructure and mechanical properties of the Sanicro 25 steel after ageing

Purpose: The purpose of the research was to determine and analyse the changes in the microstructure and mechanical properties of the Sanicro 25 steel in the as-received condition and after ageing at 600, 650 and 700°C fo...

Management decision-making algorithm development for planning activities that reduce the production risk level

Purpose: Algorithm development for a measures phased expert assessment to reduce production risk at an industrial enterprise to adapt the expert method to the conditions for specific problem solving. Design/methodology/a...

Semi-continuous caster for plate

Purpose: Development of a semi-continuous caster that can cast a single plate and a clad plate of Al-40%Sn-1%Cu alloy used for sliding bearings. Design/methodology/approach: A semi-continuous caster to cast a single plat...

Download PDF file
  • EP ID EP189317
  • DOI -
  • Views 140
  • Downloads 0

How To Cite

L. A. Dobrzański, A. Dobrzańska-Danikiewicz, T. G. Gaweł (2016). Individual implants of a loss of palate fragments fabricated using SLM equipment. Journal of Achievements in Materials and Manufacturing Engineering, 77(1), 24-30. https://europub.co.uk/articles/-A-189317