INDOOR AIRBORNE BACTERIA AND FUNGI ATDIFFERENT BACKGROUND AREA IN NURSERIES AND DAY CARE CENTRES ENVIRONMENTS

Journal Title: Journal CleanWAS - Year 2017, Vol 1, Issue 1

Abstract

Respiratory symptoms among children cases increased dramatically was believe due to poor indoor air quality. Nursery and day care centre (DCC) appear to be the site of exposure and transmission of airborne microorganism between children. This study aims to assess the relation between the colony forming unit level of biological contaminant (bacteria and fungi) between urban and suburban location correlate with indoor air quality (IAQ) parameters. Besides, the other aims for this study were to identify the types of an airborne pathogenic microbial contaminant in the nursery and DCC. The airborne microbial sampling was done by using Surface Air System Indoor air Quality (SAS IAQ), which taken at the end of June until early August 2015. This study presents the diversity of indoor airborne bacteria and fungi in the nursery and DCC demonstrated in relation to occupancy, location, and ventilation system. Correlation between bacteria and fungi counts and the other IAQ parameters (temperature, RH, CO2, and CO) was unable to be studied due to instruments limitation. Counts of airborne bacteria and fungi were measured as colony forming units (CFU) grown on agar plates. CFU counts were compared by sampling sessions and sampling locations (babies room, a kindergarten room, and control room). Fluctuations in bacteria and fungi counts in such conditions were observed. Three groups of culturable bacteria were identified: Grampositive cocci, Gram-positive bacilli, and Gram-negative bacteria while five genera of fungi successfully identified were Aspergillus, Penicillium, Rhizopus, MucorandChrysonilia. Certain bacteria isolated from this study were identified at a species level by 16s rRNA amplification including S. haemolyticus, A. baumannii, P. stutzeri, M. osloensis, M. luteus, B. subtilis, Rothia spp., and Roseomonasspp. Overall findings suggest that IAQ level in investigated sites was at poor level due to high bacteria and fungi concentrations with isolation of some opportunistic pathogenic microorganism. This pathogenic microorganism will cause adverse health reaction especially to young children. This study will provide a baseline of hygienic indoor air quality in nursery and day care centre.

Authors and Affiliations

Shahidah N. , Hasnah, S, Shuhaili, S, Syamzany, A. , Mohd Shukri , M.A.

Keywords

Related Articles

CURRENT ANALYTICAL METHODS FOR AMLODIPINE AND ITS FORMULATIONS: A REVIEW

The use of amlodipine is very common due to the effects of amlodipine on hypertension and coronary artery disease (CAD) like chronic stable angina, vasospastic angina (Prinzmetal’s or variant angina), and angiographicall...

CHNS ANALYSIS TOWARDS FOOD WASTE IN COMPOSTING

High food waste generation in Malaysia that reached up to 15, 000 tonnes per day assign for major problems towards environment, economy and social aspect. Alternative method had been studied for the past years, but compo...

DISTRIBUTION PATTERN OF RARE EARTH ELEMENTS IN SOFT TISSUE OF SACCOSTREA CUCULLATA IN TERENGGANU AND EAST JOHOR COASTAL WATERS

This study determined the concentration and accumulation pattern of REEs in the soft tissue of Saccostrea cucullata with respect to interspatial variability. Variability in the concentration of REEs in soft tissue of S....

BACTERIAL POPULATION STUDY IN OIL-CONTAMINATED AND UNCONTAMINATED SOILS

Soil provides a vital habitat primarily for bacteria to continue the process of biogeochemical cycle. The remarkable metabolic diversity and capacity of the soil bacteria is increasingly being harnessed for the benefit o...

ASSESSMENT OF TRACE METALS USING CHEMOMETRIC ANALYSIS IN KUANTAN RIVER, EAST COAST MALAYSIA

Chemometric techniques were applied to identify and assess the trace metals of Kuantan River water. Water samples from nine sampling stations were taken from downstream of the estuary towards the upstream of Kuantan Rive...

Download PDF file
  • EP ID EP261010
  • DOI 10.26480/jcleanwas.01.2017.35.38
  • Views 130
  • Downloads 0

How To Cite

Shahidah N. , Hasnah, S, Shuhaili, S, Syamzany, A. , Mohd Shukri, M. A. (2017). INDOOR AIRBORNE BACTERIA AND FUNGI ATDIFFERENT BACKGROUND AREA IN NURSERIES AND DAY CARE CENTRES ENVIRONMENTS. Journal CleanWAS, 1(1), 35-38. https://europub.co.uk/articles/-A-261010