Influence of elbow angle on the reliability and validity of bioelectrical impedance analysis

Journal Title: Journal of Sports Medicine and Therapy - Year 2017, Vol 2, Issue 4

Abstract

Hand-to-hand bioelectrical impedance (HH BIA) is a low-cost method to estimate percent body fat (%BF). The BIA method is consistently reliable, but questions on validity remain. We have observed anecdotally that elbow position can render consistently different measures of %BF while using HH BIA, thus leading to the question: Does elbow angle influence the validity of measures derived using HH BIA? The purpose of this study was to assess the effect of elbow position (i.e., IN=flexed to 90° versus OUT=fully extended) on the reliability of HH BIA on 44 male and 24 female healthy adults (age=21±2 yrs, BMI=23±3). An additional aim was to assess the validity of the HH BIA %BF on a subset of subjects (n=12) using air displacement plethysmography (BOD POD®) as the criterion measure. The IN position was ~4%BF lower than the OUT position for HH BIA (p=0.05, effect size=0.67). Measures of %BF for both trials for the IN [intraclass correlation coefficient (ICC)=0.99, coefficient of variation (CV)=2.99%] and OUT (ICC=0.99, CV=1.48%) conditions were highly reliable. On the subsample, the OUT (18.3±6.7 %BF) position exceeded both the IN (14.5±7.4 %BF) and the BOD POD® (16.1±7.8 %BF) measures (p<0.05); however, IN and BOD POD® measures of %BF did not differ (p=0.21). These findings support that HH BIA is a reliable measure at both elbow positions; however, %BF estimations vary considerably (~4%) with respect to the criterion measure depending on elbow position. The OUT position was found to overestimate criteria %BF. Further research may reveal an optimum elbow angle position for HH BIA estimates of %BF.

Authors and Affiliations

Pettitt Robert W, Mehrhoff Jacob B, Mandeville David S, Murray Steven Ross

Keywords

Related Articles

Retrospective Analysis of Non-Contact ACL Injury Risk: A Case Series Review of Elite Female Athletes

Background: Literature on ACL injury is limited when assessing for the presence and interaction of multiple risk factors simultaneously. Identifying risk factor interaction may increase the impact of prevention programme...

The Courage to implement Samplings to evaluation efficiency Medical Clinics OECD

We are able to test with statistic method Based Evidence Medicine the new Medicaments on common World Market or the new Medical Devices - Orthopaedic implants. Of course, with usage the same principles we could Tests sim...

The Utility of Acupuncture in Sports Medicine: A Review of the Recent Literature

Introduction: Acupuncture is a practice that has been used to treat multiple medical conditions for thousands of years and is one of the most popular alternative treatments applied in Western medical practice. Acupunctur...

Differences between traditional Visualization and Virtual reality on motor performance in novel climbers

This paper analyses the effect of virtual reality visualization (VRV) on climbers, with respect to the traditional visualization methodology. The study sample was made up of 21 novel climbers: Control Group CG (N=7), Tra...

Bergamot Polyphenolic Fraction supplementation improves metabolic balance, endothelial function and maximal oxygen uptake in athletes

Background: The study aimed to evaluate the effects of a 4-week Bergamot Polyphenolic Fraction (BPF Gold; Bergamet Sport) supplementation on serum nitric oxide (NO), asymmetric dimethyl-arginine (ADMA), Endopat indices o...