INFLUENCE OF SELECTED FACTORS FOR LOCALIZATION ACCURACY IN THE OPTICAL VORTEX INTERFEROMETER

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 1

Abstract

Optical vortices were intensively studied during the last decade. In the literature there are papers presenting applications of the optical vortices. The regular net of optical vortices generated by the three plane waves interference allows for the new kind of the interferometer - the Optical Vortex Interferometer (OVI). The precision of the OVI depends on the localization accuracy and the phase reconstruction. The localization methods lead to errors if we use beamsplitters with coatings changing the polarization state of the light. There are six beamsplitters used in this interferometer. In the setup we used non-polarizing coatings. We observed a pleochroism effect which occurs in these coatings. It is the cause of errors in the localization of optical vortices. In this paper we study the effect of pleochroism and we show the way to avoid errors in the localization of optical vortices in the OVI.

Authors and Affiliations

EWA FRĄCZEK, JANUSZ MROCZKA

Keywords

Related Articles

LIFTING BASED COMPRESSION ALGORITHM FOR POWER SYSTEM SIGNALS

The paper concerns the problem of power system signals compression with possible application in system monitoring and control. The proposed compression algorithm for power system signals ensures efficient use of availabl...

RESEARCH ON HYSTERESIS OF TRIGGERING PROBES APPLIED IN COORDINATE MEASURING MACHINES

The article presents selected results of investigation of triggering probe hysteresis in coordinate measuring machines. The research covered the hysteresis of pretravel of one-stage triggering probes equipped with a swit...

TWO-PARAMETER MEASUREMENTS AND SIGNAL CONDITIONING IN DOUBLE-CURRENT SUPPLY FOUR-TERMINAL RESISTANCE CIRCUITS

A new type of the four-terminal (4T) bridge circuit unconventionally supplied by current sources connected in parallel to opposite arms, named double current bridge (2J) is presented. It has two different outputs from bo...

NTERCOMPARISON OF WATER TRIPLE POINT CELLS FROM INTIBS AND INRIM

The triple point of water defines the unit of thermodynamic temperature, kelvin, and is the most important fixed point of the International Temperature Scale of 1990. Several international comparisons of cells for the re...

THE PROBLEM OF MEASUREMENT DATA COMPLEXITY, FOR EXAMPLE OF THE GENERAL MODEL OF THE CENTRAL RESPIRATORY GENERATOR AND RECURRENT PLOTS ANALYSIS

The purpose of this modeling paper is to show and, in some extent, to explore the utility of one nonlinear tool, the recurrence plot, in assessing physiological systems and states, for example of the respiratory system....

Download PDF file
  • EP ID EP96826
  • DOI -
  • Views 53
  • Downloads 0

How To Cite

EWA FRĄCZEK, JANUSZ MROCZKA (2008). INFLUENCE OF SELECTED FACTORS FOR LOCALIZATION ACCURACY IN THE OPTICAL VORTEX INTERFEROMETER. Metrology and Measurement Systems, 15(1), 3-8. https://europub.co.uk/articles/-A-96826