Interchangeability of corneal curvature and asphericity measurements provided by three different devices
Journal Title: International Journal of Ophthalmology - Year 2019, Vol 12, Issue 3
Abstract
"AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles. METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1y were included. In all cases, a corneal curvature analysis was performed with IOL-Master (IOLM), iDesign 2 (ID2), and Sirius systems (SIR). Differences between instruments for flattest (K1) and steepest (K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity (Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21 (P<0.001), -0.12±0.36 (P=0.046) and -0.32±0.36 D (P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33 (P<0.001), -0.08±0.43 (P=0.265) and -0.39±0.38 D (P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance (0.49 D, P=0.011; 0.55 D, P=0.386; 0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis (26.68º, 33.83º and 18.37º, P≥0.121) and for Q between SIR and ID2 (0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provide by the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes."
Authors and Affiliations
David P. Piñero
Refractive errors and biometry of primary angle-closure disease in a mixed Malaysian population
"AIM: To assess the refractive status, anterior chamber depth (ACD) and axial length (AL) of patients with primary angle-closure disease (PACD). METHODS: Retrospective cohort. Data was collected from charts of all PACD p...
Combined Descemet stripping automated endothelial keratoplasty and intravitreal dexamethasone implant for concomitant pseudophakic bullous keratopathy and cystoid macular edema
Letter to the editor
Structure-function relationship comparison between retinal nerve fibre layer and Bruch’s membrane opening-minimum rim width in glaucoma
"AIM: To evaluate and compare structural optical coherence tomography (OCT)-based parameters, such as Bruch’s membrane opening-minimum rim width (BMO-MRW), and retinal nerve fiber layer (RNFL) thickness in glaucoma patie...
Efficacy and safety of micropulse laser trabeculoplasty for primary open angle glaucoma
"AIM: To evaluate the efficiency and safety of micropulse laser trabeculoplasty (MLT) for primary open angle glaucoma (POAG) patients. METHODS: Retrospective study. POAG patients undergoing MLT in Peking University Third...
Anterior proliferative vitreoretinopathy in a patient with Coats disease
Letter to the Editor