Interlaboratory comparisons of the calibration results of signal generator

Abstract

<p>The data of interlaboratory comparisons of calibration results of signal generators at three calibration points are presented. The choice of methodology for processing the results of interlaboratory comparisons is made taking into account the long-term drift of the comparison sample. The modernization and research of the comparison sample for interlaboratory comparisons of calibration results of signal generators are carried out. The assigned values for the three calibration points and their extended uncertainties are determined. Expressions are obtained for the approximation of the long-term drift of the comparison sample and uncertainty budgets for all assigned values of the comparison sample at the frequencies of 130 MHz, 168 MHz and 223 MHz are compiled.</p><p>The interlaboratory deviations of the results obtained by laboratories are determined and the consistency of the data obtained using the E<sub>n</sub> and z indicators is estimated. This characterizes the reliability and accuracy of laboratory measurement results, and is also important for confirming technical competence. The presented results of interlaboratory comparisons of the signal generator calibration results show that all participating laboratories meet the requirements by the E<sub>n</sub> indicator. At the same time, two out of ten laboratories require certain substantial corrective measures, as they do not meet the requirements by the z indicator.</p><p>It is established that the E<sub>n</sub> indicator is not always self-sufficient. It largely characterizes only the reliability of laboratory measurement results. For this purpose, the z indicator is more informative, which provides more information on the accuracy of laboratory measurement, that is, the proximity of measurement results to the true value.</p>

Authors and Affiliations

Oleh Velychko, Sergii Shevkun, Tetyana Gordiyenko

Keywords

Related Articles

Design of the conceptual implementation of an apparatus with the induced heat and mass transfer for vaporization and rectification

<p>The need to find solutions to problems on the efficient use of energy resources has been substantiated, under conditions for meeting the requirements to the environmental sustainability of production in the process of...

Technological features in obtaining highly effective hydrogel dressings for medical purposes

The new technology of formation of hydrogel dressings for medical purposes, containing particles of silver was developed. To obtain metal-containing composite hydrogels, we proposed a high-tech single-stage method, which...

Development of the method for the formation of one-dimensional contours by the assigned interpolation accuracy

<p>The purpose of the study is to develop a method for the formation of a one-dimensional contour with provision of a given accuracy of interpolation. Determination of the accuracy of interpolation relies on the formatio...

Analysis of the efficiency of space­time access in the mobile communication systems based on an antenna array

<p class="Default">We performed analysis of effectiveness of various methods and criteria of space-time processing of the signals by an adaptive antenna array with a view to identifying the algorithm suitable for using i...

Determining high quasi­hydrostatic pressure up to 7 GPa at a temperature to 1,400 °С using resistive sensors

<p>A differential method for measuring high quasi‒hydrostatic pressures for six‒punch pressing installations has been constructed by building a load‒carrying characteristic р=f(Q), where p is the value for pressure in a...

Download PDF file
  • EP ID EP666460
  • DOI 10.15587/1729-4061.2019.166504
  • Views 88
  • Downloads 0

How To Cite

Oleh Velychko, Sergii Shevkun, Tetyana Gordiyenko (2019). Interlaboratory comparisons of the calibration results of signal generator. Восточно-Европейский журнал передовых технологий, 3(9), 14-20. https://europub.co.uk/articles/-A-666460