INTERPRETATION OF RESULTS OF THE PUMPING TEST IN UNSTEADY FLOW IN DIFFERENT HYDROGEOLOGICAL CONDITIONS
Journal Title: Biuletyn Państwowego Instytutu Geologicznego - Year 2011, Vol 445, Issue 445
Abstract
Test pumpings under conditions of transient flow are still rarely used in documenting groundwater resources, particularly in relation to fresh water. This paper presents interpretation of the results of pumping test conducted in three wells (A, B and C) characterized by different hydrogeological conditions. All of them were multi-step tests. Interpretations were made using the AquiferWin32 software. We examined the correctness of the selection scheme and the timing of the test. Depending on the hydrogeological model, different methods of interpretation were implemented. Correct interpretation of hydrodynamic tests depends largely on the proper design of the test method (pumping scheme). Very important is also the selection of an appropriate measuring apparatus and appropriate devices for securing the assumed pumping regime. These factors ensure the reliability of the results (measured depression at the constant discharge). Only reliable measurement data, in conjunction with a properly matched method of interpretation of the hydrogeological conditions, will allow for reliable calculation of the filter parameters of the aquifer.
Authors and Affiliations
Bogusław BIELEC, Grażyna HOŁOJUCH
ANALYSIS OF PAINTING LAYERS IN ORTHODOX CHURCH ICON PAINTINGS AT KORYTNIKI (SOUTHEASTERN POLAND)
The main aim of this work is to identify the grounds and mineral pigments in icons from ST Demetrius Orthodox Church at Korytniki near Przemyśl, collected at the Orthodox Art Department of the Castle Museum in Łańcut. Th...
PIERWSZY W POLSCE SYSTEM WCZESNEGO OSTRZEGANIA O ZAGROŻENIU OSUWISKOWYM W CZASIE RZECZYWISTYM NA PRZYKŁADZIE WYBRANYCH LOKALIZACJI W BESKIDZIE NISKIM
W artykule zaprezentowano nowoczesny system wczesnego ostrzegania i monitoringu osuwisk, zainstalowany w Beskidzie Niskim w województwie małopolskim. System jest pierwszym tego typu w Polsce i został zbudowany w ramach...
ANALIZA PARAMETRYCZNA KRZYWEJ PRZEJŚCIA ZNACZNIKA PRZEZ KOLUMNĘ FILTRACYJNĄ
Kształt krzywej przejścia znacznika przez kolumnę filtracyjną jest zdeterminowany przez udział różnych mechanizmów migracji, zachodzących podczas transportu danej substancji. Na podstawie interpretacji krzywej przejścia...
THE SMALLEST AND THE ONLY CARPATHIAN SPA WITH SULPHIDE WATERS AT WAPIENNE NEAR GORLICE
In the paper intakes of sulphide therapeutic waters at Wapienne Spa, the only Carpathians health resort possessing sulphide therapeutic waters are described. There exist water intakes: springs Kamila and Marta and wells...
ROZMIESZCZENIE ZASOBÓW PROGNOSTYCZNYCH I PERSPEKTYWICZNYCH KOPALIN ILASTYCH CERAMIKI BUDOWLANEJ NA OBSZARZE POLSKI
Dla kopalin ilastych ceramiki budowlanej wyznaczono na obszarze Polski ponad sto obszarów prognostycznych i 280 obszarów perspektywicznych. Podstawowe znaczenie mają kopaliny czwartorzędowe (zwłaszcza iły zastoiskowe) or...