INTRA- AND INTER-EXAMINER RELIABILITY IN ANGULAR MEASUREMENTS OF THE KNEE WITH A SMARTPHONE APPLICATION

Journal Title: Human Movement - Year 2017, Vol 18, Issue 2

Abstract

Purpose. Goniometric smartphone applications to measure joint angles offer greater practicality and accessibility, which makes them potential alternatives to a conventional goniometer. The aim of the present study was to evaluate the intra- and inter-examiner reliability in measuring the angles of the range of motion of the knee with the use of the ROM© goniometric smartphone application. Methods. The total of 34 young healthy women with an at least 20° limitation in knee extension range of motion participated in the study. Angular measurements of knee flexion in the dominant leg were performed with the aid of the smartphone application by three trained examiners for the evaluation of the inter-examiner reliability. The second evaluation was carried out after a 48-hour period for the determination of the intra-examiner reliability. Results. The proposed method demonstrated excellent intra-examiner (intra-class correlation coefficient [ICC] > 0.80) and inter-examiner (ICC > 0.90) reliability, with good intra-examiner (r > 0.85) and strong inter-examiner (r > 0.90) correlations (p < 0.0001), an intra-examiner coefficient of determination (R2) of 0.75, inter-examiner R2 of 0.91, and good level of agreement on the Bland-Altman plots for the measures. Conclusions. The findings reveal that the ROM© goniometric smartphone application can be considered a useful tool for the evaluation of the knee range of motion in healthy women. Key words: smartphone, joint range of motion, knee, reproducibility of measurements

Authors and Affiliations

VIVIANE DERHON, RAFAEL APARECIDO SANTOS, MICHELLE BRANDALIZE, DANIELLE BRANDALIZE, LUCIANO PAVAN ROSSI

Keywords

Related Articles

The body as a value in the axiology of disabled persons

The body adopts the specific contents, functions, and places of the axiological system in persons with a disability. It can adopt the contents of ultimate, instrumental, vital, utilitarian, cultural, moral, religious, an...

A paradigm for identifying ability in competition: The association between anthropometry, training and equipment with race times in male long-distance inline skaters – the ‘Inline One eleven’

Purpose. The association between anthropometric and training characteristics on an athlete’s performance has been investigated in swimmers, cyclists and runners, but not in inline skaters. The aim of this study was to in...

Effects of interval training-based glycolytic capacity on physical fitness in recreational long-distance runners

Purpose. The aim of this study was to investigate the influence of 8-week-long interval training (targeting glycolytic capacity) on selected markers of physical fitness in amateur long-distance runners. Methods. The stud...

COMPARISON OF NETWORK PROCESSES BETWEEN SUCCESSFUL AND UNSUCCESSFUL OFFENSIVE SEQUENCES IN ELITE SOCCER

Purpose. The study aimed to compare social network analysis (SNA) general measures and centrality levels of successful and unsuccessful offensive sequences performed by elite national teams in 64 matches of the FIFA Worl...

&nbsp;EFFECTS&nbsp;OF DIFFERENT INTENSITIES OF FLEXIBILITY TRAINING ON EXPLOSIVE FORCE

&nbsp;[b]Purpose. [/b]To verify whether there are changes in the&nbsp;performance levels of the explosive force when the same muscle group previously&nbsp;under­went different intensities of flexibility training (stretch...

Download PDF file
  • EP ID EP275685
  • DOI 10.1515/humo-2017-0011
  • Views 92
  • Downloads 0

How To Cite

VIVIANE DERHON, RAFAEL APARECIDO SANTOS, MICHELLE BRANDALIZE, DANIELLE BRANDALIZE, LUCIANO PAVAN ROSSI (2017). INTRA- AND INTER-EXAMINER RELIABILITY IN ANGULAR MEASUREMENTS OF THE KNEE WITH A SMARTPHONE APPLICATION. Human Movement, 18(2), 38-43. https://europub.co.uk/articles/-A-275685