INTRAOPERATIVE GAMMA PROBE APPLICATION IN PATIENTS PRE-DIAGNOSED WITH OSTEOID OSTEOMA

Abstract

Introduction: Osteoid osteoma is a benign but painful bone tumor that is treated with the excision of the nidus. Due to difficulties in reaching the tumor, intraoperative localization may be needed for complete excision without unnecessary resection of the surrounding bone. Aim: The aim of this study was to evaluate the effectiveness of intraoperative gamma probe application in the preoperative planning and for intraoperative localization of osteoid osteoma. Material and Method: The study included a total of 26 patients, comprising 10 females and 16 males with a mean age of 19.6 years (range, 6-45 years), who were pre-diagnosed with osteoid osteoma based on clinical and radiological findings. All patients were admitted for surgery following bone scintigraphy. All operations were performed with the use of a gamma probe. Results: Clinical results were obtained from the postoperative pain evaluation and excised bone tissue fragments were evaluated histopathologically. Localisation of the lesion area was made intraoperatively using a gamma probe in all patients. A statistically significant difference was determined between the radioactivity counts in the normal peripheral bones of the lesion and the lesion area itself (p<0.001). The ratio of lesion to normal tissue was 4/1 on average. The radioactivity level dropped by 62% on average (30%-90%) in the cavity cleaned after post-resectional excision of the pathological tissue. The radioactivity counts in the cavity after resection were found to be significantly lower than those of the lesion area before resection (p<0.001). Of the 26 patients included in the study, 21 were diagnosed with osteoid osteoma as a result of the histopathological analysis. Of 5 patients with a diagnosis additional to the osteoid osteoma, 2 were diagnosed with infection, 2 were diagnosed with enchondroma, and 1 was diagnosed with osteosarcoma. With the exception of the patient diagnosed with osteosarcoma, the lesions were excised using the gamma probe method in the remaining 4 patients. Conclusion: The use of a gamma probe in intraoperative localization following a preoperative injection of Tc99m MDP, is an easy and safe method that helps in the localization of osteoid osteoma nidus during surgery and guides a limited but complete resection of the tumor. Key Words: Osteoid Osteoma, Gamma Probe, Scintigraphy

Authors and Affiliations

M. D,Serdar Altindag

Keywords

Related Articles

“Factors of raised C-reactive protein as a potential determinant of Diabetic patients and Risk factor for Coronary Heart Disease”

Elevated C-reactive protein (CRP) levels have previously been described before the onset of type 1 diabetes and gestational diabetes. We hypothesized that inflammation, as reflected by elevated CRP levels, can help predi...

To Study Of Socio-Demographic Profile of Road Traffic Accidents

Background- Road traffic accidents are the only public health problem for which society and decision makers still accept death and disability among young people on large scale. Methods-50 cases of RTAs caused by accident...

PROPHYLACTIC VERSUS REGULAR USE OF ANTIBIOTICS IN CESAREAN SECTION

The aim of this study was to compare the prophylactic use of antibiotic verses regular antibiotics in caesarean section. Background: Present study was conducted at Shri Vinoba Bhave Civil Hospital, Silvassa in the depar...

A DESCRIPTIVE STUDY OF MRI IN ORAL CANCER PATIENTS AT A TERTIARY CARE HOSPITAL IN JAIPUR.

Aim: To describe the observations of MRI in oral cancer patients as per Tumor size, Depth of tumor invasion, Bone involvement and T-staging assuming histopathology as gold standard. Material & methods: 70 patients with b...

Spectrum of cytomorphological diagnosis of palpable head and neck lesions - in Central India.

Back ground: Lump in head and neck lesions are one of the most common lesions attending OPD of various departments making patients become very anxious. FNAC is a quick and non-invasive OPD procedure help patients to reli...

Download PDF file
  • EP ID EP546770
  • DOI -
  • Views 68
  • Downloads 0

How To Cite

M. D, Serdar Altindag (2018). INTRAOPERATIVE GAMMA PROBE APPLICATION IN PATIENTS PRE-DIAGNOSED WITH OSTEOID OSTEOMA. International Journal of Medical Science and Diagnosis Research (IJMSDR), 2(5), 69-77. https://europub.co.uk/articles/-A-546770