Investigation of the Anomalous Dry Berth Track Corrosion
Journal Title: INTERNATIONAL JOURNAL OF ENGINEERING TRENDS AND TECHNOLOGY - Year 2014, Vol 9, Issue 4
Abstract
Severe corrosion rates were observed in a relatively new track rail system used in Dubai Maritime City. Similar track system in a nearby location, Gaddaf, with similar temperature and humidity profile did not exhibit similar results. The purpose of this research is to investigate the root cause for the abnormal corrosion behavior of DMC tracks and to study the differences between DMC and Gaddaf track materials in terms of microstructure, chemical composition, mechanical behavior and corrosion resistance characteristics.
Authors and Affiliations
Saud Aldajah , Prakash Bhalchandra , Arif Ustadi , Zakarya AlJassmi
32×32 Colour Image Steganography
— The word steganography is originally derived from Greek words which mean “Hidden Writing”.Due to the rapid growth of usage of internet over high bandwidth and low cost computer hardware has propelled the explosiv...
Conventional Fuel Injection System in Two-Stroke Engines
Carburetted 2-stroke engines are a worldwide pandemic. There are over 50 million 2-stroke cycle engines in Asia alone, powering motorbikes, mopeds, “three-wheelers”, “auto-rickshaws”, “tuk-tuks”, and “tricycles”....
Reactive Power Optimization Using Differential Evolution Algorithm
-In this Reactive power optimization is a nonlinear, multi-variable, multi-constrained programming problem, which makes the optimization process multifaceted. In this paper, based on the characteristics of reactive...
Image Compression using Wavelet and SPIHT Encoding Scheme
The traditional image coding technology uses the redundant data in an image to compress it. But these methods have been replaced by digital wavelet transform based compression method as these methods have high spee...
Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System
his paper illustrates a study on improvement of rotor angle and dynamic performance of AC/DC interconnected system. High voltage direct current transmission is an economic way for long distance power delivery and/o...