Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city

Journal Title: Environmental Health Engineering and Management Journal - Year 2018, Vol 5, Issue 3

Abstract

Background: The use of daylight in offices has become an effective strategy to improve the quality of indoor space and energy efficiency. There is enough potential to have daylight autonomy in Kerman as a city with more than 300 sunny days a year. Therefore, this study aimed to investigate the relationship between facades configuration and the amount of daylight in office buildings of Kerman. Methods: This study was carried out based on the simulation in DesignBuilder software (DBS). In this study, 36 typical rooms, with the same physical characteristics (4 m×6 m×4 m), with window-to-wall ratio (WWR) between 10- 90% with four overhang depths (0, 0.5, 1 and 1.5 m) were modeled. Results: Based on daylight utilization, the results indicate that an optimal WWR for a room with 1 m overhang depth ranged from 50% to 70%. Also, the room with 0.5 m overhang depth and without overhang, had suitable daylight while WWR was at least 50%, but the room with 1.5 m depth would not encounter glare problem even when WWR was 90%. Conclusion: The results confirm that overhang depth and WWR have significant effect on daylight parameters such as daylight factor (DF), work plane illuminance (WPI), and WPI ratio. Hence, these insights can be useful for designers to design buildings with lower energy use and higher daylight quality, when enough light is provided in office rooms.

Authors and Affiliations

Ali Yazhari Kermani , Farshad Nasrollahi , Mohammadjavad Mahdavinejad

Keywords

Related Articles

Evaluation of Cd phytoremediation by Portulaca oleracea irrigated by contaminated water

Background: Worldwide, more than 10 million regions with an area of more than 20 million hectares are considered contaminated soils. The expansion in industrial activities and urbanization has led to accumulation of hi...

Screening of camphene as a potential inhibitor targeting SARSCoV- 2 various structural and functional mutants: Through reverse docking approach

Background: SARS-CoV was first identified in 2003 but SARS-CoV-2, which gained its recognition again in 2019 as COVID-19, has been a crucial threat worldwide and has caused more death rates than the SARS-CoV but till n...

Innovative biofiltration materials for H2S removal from biogas

Background: Following an extensive examination of various biofiltration packing materials within a typical bioreactor (a biofilter) is aiming to remove hydrogen sulfide (H2S) in the raw biogas. Methods: Both biochar (p...

Application of heterogeneous catalytic ozonation process for treatment of high toxic effluent from a pesticide manufacturing plant

Background: The discharge of untreated wastewater containing toxic and resistant compounds into the environment is a serious threat for ecosystems. Therefore, this study was conducted to evaluate the treatment of poiso...

Optimizing functions of coagulants in treatment of wastewater from metalworking fluids: Prediction by RSM method

Background: Coagulation is a treatment procedure for metalworking fluids (MWFs). This study aimed to optimize coagulation using four coagulants and compare the results. Methods: In this research, the outputs of a coagul...

Download PDF file
  • EP ID EP45336
  • DOI 10.15171/EHEM.2018.18
  • Views 386
  • Downloads 0

How To Cite

Ali Yazhari Kermani, Farshad Nasrollahi, Mohammadjavad Mahdavinejad (2018). Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city. Environmental Health Engineering and Management Journal, 5(3), -. https://europub.co.uk/articles/-A-45336