Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city

Journal Title: Environmental Health Engineering and Management Journal - Year 2018, Vol 5, Issue 3

Abstract

Background: The use of daylight in offices has become an effective strategy to improve the quality of indoor space and energy efficiency. There is enough potential to have daylight autonomy in Kerman as a city with more than 300 sunny days a year. Therefore, this study aimed to investigate the relationship between facades configuration and the amount of daylight in office buildings of Kerman. Methods: This study was carried out based on the simulation in DesignBuilder software (DBS). In this study, 36 typical rooms, with the same physical characteristics (4 m×6 m×4 m), with window-to-wall ratio (WWR) between 10- 90% with four overhang depths (0, 0.5, 1 and 1.5 m) were modeled. Results: Based on daylight utilization, the results indicate that an optimal WWR for a room with 1 m overhang depth ranged from 50% to 70%. Also, the room with 0.5 m overhang depth and without overhang, had suitable daylight while WWR was at least 50%, but the room with 1.5 m depth would not encounter glare problem even when WWR was 90%. Conclusion: The results confirm that overhang depth and WWR have significant effect on daylight parameters such as daylight factor (DF), work plane illuminance (WPI), and WPI ratio. Hence, these insights can be useful for designers to design buildings with lower energy use and higher daylight quality, when enough light is provided in office rooms.

Authors and Affiliations

Ali Yazhari Kermani , Farshad Nasrollahi , Mohammadjavad Mahdavinejad

Keywords

Related Articles

A survey of knowledge, attitude, and performance of Kerman residents on segregation and recycling of household solid wastes during COVID-19 period

Background: Awareness, knowledge, and attitude towards waste management, environmental factors of waste disposal sites and citizens’ as well as waste generators’ behaviors should be considered for implementing a waste...

The influence of gaseous ozone on the growth of fungi isolated from clinical and environmental samples

Background: Disinfection is performed in our laboratory using sodium hypochlorite, glutaraldehyde, alcohol, or hydrogen peroxide. All these products are known for their harmful side effects on human and ecological heal...

Chromium removal and water recycling from electroplating wastewater through direct osmosis: Modeling and optimization by response surface methodology

Background: Considering the carcinogenic effects of heavy metals, such as chromium, it is essential to remove these elements from water and wastewater. Direct osmosis is a new membrane technology, which can be a proper...

Organoleptic and palatability properties of drinking water sources and its health implications in Ethiopia: a retrospective study during 2010-2016

Background: This retrospective study aimed to investigate the physicochemical properties of drinking water sources in Ethiopia and compare the water quality with the health-based target. For this purpose, the water quali...

Assessment of aflatoxin exposure using urine biomarker in pregnant and non-pregnant women in Yazd, Center of Iran

Background: Aflatoxins (AFs) are one of the most prevalent toxins, which long-term exposure to them could be a risk factor for liver cancer. AFM1 is the hydroxylated metabolite of AFB1, therefore, the presence of AFM1 in...

Download PDF file
  • EP ID EP45336
  • DOI 10.15171/EHEM.2018.18
  • Views 395
  • Downloads 0

How To Cite

Ali Yazhari Kermani, Farshad Nasrollahi, Mohammadjavad Mahdavinejad (2018). Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city. Environmental Health Engineering and Management Journal, 5(3), -. https://europub.co.uk/articles/-A-45336