Investigations of Response Time Parameters of a Pneumatic 3/2 Direct Acting Solenoid Valve Under Various Working Pressure Conditions

Journal Title: Engineering, Technology & Applied Science Research - Year 2013, Vol 3, Issue 4

Abstract

In pneumatic circuits, a solenoid valve is a key component for controlling and directing pneumatic energy. The solenoid valve functional performances are defined as response time parameters with respect to its actuations in terms of direction changing time. This paper aims to present response time parameters of solenoid valves under various working pressures. An experimental setup is employed in order to measure response time with reference to the input signals. The response time plays significant role for evaluating the valve performance in sensitive applications. The response time parameters includes the on delay, the off delay, the on time, the off time, the cycle time and the switching frequency. In this experimental investigation the influence of various input pressure conditions is recorded and tabulated. Valves with varying orifice diameter are employed and the investigation reveals the influence of orifice diameter in response time variations. The newly-proposed six response time parameters can be used to rate and select the appropriate valve for various industrial applications.

Authors and Affiliations

K. A. Venkataraman, K. Kanthavel, B. Nirmal Kumar

Keywords

Related Articles

Optimal Power Factor for the Reactive Load of Small Hydro Power Plants

This article explores the operation algorithm of an excitation regulator of synchronous generators of small Hydro Power Plants (HPPs). The aim is to provide optimum economic parameters, consistent with the dynamically ch...

Formulation of Low Peclet Number Based Grid Expansion Factor for the Solution of the Convection Diffusion Equation

Convection-diffusion problems, due to its fundamental nature, are found in various science and engineering applications. In this research, the importance of the relationship between grid structure and flow parameters in...

A Research on the Synchronization of Two Novel Chaotic Systems Based on a Nonlinear Active Control Algorithm

The problem of chaos synchronization is to design a coupling between two chaotic systems (master-slave/drive-response systems configuration) such that the chaotic time evaluation becomes ideal and the output of the slave...

Effect of IT Application on Project Performance Focusing on the Mediating Role of Organizational Innovation, Knowledge Management and Organizational Capabilities

The purpose of this study is to examine the effect of IT application on project performance focusing on mediating role of organizational innovation, knowledge management and organizational capabilities using SEM. For thi...

Modeling and Parameter Optimization for Surface Roughness and Residual Stress in Dry Turning Process

The influence of some turning variables and tool overhang on surface roughness parameters and residual stress induced due to machining 6061-T6 aluminum alloy is investigated in this paper. Four input parameters (cutting...

Download PDF file
  • EP ID EP89460
  • DOI -
  • Views 267
  • Downloads 0

How To Cite

K. A. Venkataraman, K. Kanthavel, B. Nirmal Kumar (2013). Investigations of Response Time Parameters of a Pneumatic 3/2 Direct Acting Solenoid Valve Under Various Working Pressure Conditions. Engineering, Technology & Applied Science Research, 3(4), -. https://europub.co.uk/articles/-A-89460