Ion-pair HPLC Method for the Quantification of Metformin in Human Plasma and Its Application to a Pharmacokinetic Study

Journal Title: Journal of Pharmaceutical Research International - Year 2016, Vol 9, Issue 4

Abstract

Aims: To develop and validate a rapid, selective and sensitive ion-pairing HPLC-UV method for the determination of metformin in human plasma, using a conventional reverse phase column. Study Design: Experimental study. Place and Duration of Study: Department of Department of Biomedical Sciences, Faculty of Medicine, University of Medicine, “Mother Tereza” hospital center, between November 2014 and February 2015. Methodology: Ion-pair separation followed by UV detection performed on deproteinised and dichloromethane washed plasma samples was chosen for the determination of metformin. The separation was performed on an analytical LiChrocart® 100 RP 18 (125 × 4.0 mm i.d., 5 µm particle size) C18 column. A mobile phase consisting of acetonitrile and 10 mM sodium phosphate buffer (pH=6.0; 32.5:67.5, v/v) and sodium dodecyl sulfate (0.3%) was pumped at an isocratic flow rate of 1.25 mL/minute, and quantification was achieved at 236 nm using a UV/Vis DAD. Results: The calibration curves were linear (r > 0.9998) in the concentration ranges of 50-1600 ng/mL for metformin in plasma. The assay enables the measurement of metformin for therapeutic drug monitoring with a minimum detectable limit of 18 ng/ml. The coefficients of variation for inter-day and intra-day assay were within the range of clinical usefulness. Absolute recovery was found to be > 90% for all three concentrations of plasma quality controls studied. Conclusion: The proposed method was found to be rapid, precise and accurate for quantification of metformin in human plasma. This method was successfully applied to a pharmacokinetic study at humans through oral administration.

Authors and Affiliations

Eva Troja, Leonard Deda, Gëzim Boçari

Keywords

Related Articles

Fed Bioequivalence Studies for Immediate Release Drug Products: Beneficial or Wastage?

Aims: The present study was undertaken to understand the need of fed bioequivalence studies for immediate release pharmaceutical products and thereby evaluating the relative appropriateness of guidelines given by the Eur...

Correlation of Total Secondary Sulfur Compounds, Total Phenols and Antioxidant Capacity in the Ramsons and Garlic

Aims: This study explores the total quantity of sulfur secondary metabolites in the plant organs of garlic and ramsons, the content of total phenol and their correlation to the antioxidant capacity (AOC). There are diffe...

Investigation of Colorant FD&C Yellow No. 5 Stability in Pharmaceutical Syrup Containing Ascorbic Acid and the Optimal Storage Condition

Stability of colorant FD&C Yellow No. 5 and ascorbic acid (AA) in pharmaceutical KndCold syrup under different storage conditions (Standard conditions, temperature variation, sunlight presence, and sodium hydroxide addit...

Comparative Phytochemical Screening and In vitro Evaluation of Biological Activities between Aqueous and Ethanolic Extract of Momordica charantia L. Fruits

Aims: The study was conducted to compare the presence of different phytochemicals and biological activities like cytotoxicity, anthelmintic activity, antioxidant and free radical scavenging activities between aqueous and...

Antioxidant and Hepatoprotective Activity of Ethanol Extract of Valeriana wallichii in CCl4 Treated Rats

Aims: To screen the hepatoprotective and antioxidant activity of ethanol extract of roots of Valeriana wallichii DC (Valerianaceae)(VWE). Study Design: Animal study. Place and Duration of Study: Department of Pharmacolog...

Download PDF file
  • EP ID EP342224
  • DOI 10.9734/BJPR/2016/21436
  • Views 121
  • Downloads 0

How To Cite

Eva Troja, Leonard Deda, Gëzim Boçari (2016). Ion-pair HPLC Method for the Quantification of Metformin in Human Plasma and Its Application to a Pharmacokinetic Study. Journal of Pharmaceutical Research International, 9(4), 1-9. https://europub.co.uk/articles/-A-342224