Leak detection from liquid transmission pipelines using pressure wave technique — study of the use of two standard- and non-standard-measuring devices

Journal Title: Bulletin of the Military University of Technology - Year 2014, Vol 63, Issue 1

Abstract

This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices), placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors) joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD) pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

Authors and Affiliations

Paweł Ostapkowicz

Keywords

Related Articles

Liquid-crystalline composites for point temperature measurements

The application of cholesteric liquid crystals and composites containing them for visualization of thermal field and temperature measurement is very well known. Despite all disadvantages as limited precision and adhesion...

Evaluation of tribological properties of lubricants based on Hersey’s–Stribeck’s characteristics

The content of the paper presents the results of investigations of selected lubricants. The study led to obtaining Hersey’s-Stribeck’s curves and to comparison of the lubricating properties of lubricants belonging to dif...

Code comprehension as a distributed construction of meanings

Code comprehension, a sub-domain of reverse engineering and software maintenance, does not provide useful explanation of common situations where developers, distributed and isolated from each other in time and space, com...

Technical diagnostics of objects using active imaging

The article presents an original method of the space-time framing as a potential tool for technical diagnostics. Because of the unusual observation and measurement properties such as the selection of the observed spatial...

Analysis of dynamic displacement of reinforced concrete deep beams made of high strength concrete Part I: Analysis of dynamic displacement of a reinforced concrete deep beam made of high strength C100 grade concrete

The work presented is a three-part set of studies containing a comparative analysis of the displacement state of rectangular concrete deep beams made of concrete of different classes of very high strength, loaded dynamic...

Download PDF file
  • EP ID EP62638
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

Paweł Ostapkowicz (2014). Leak detection from liquid transmission pipelines using pressure wave technique — study of the use of two standard- and non-standard-measuring devices. Bulletin of the Military University of Technology, 63(1), 113-128. https://europub.co.uk/articles/-A-62638