Leakage Current Test at Household Refrigerator Type Urg-129 Base Standard Nasional Indonesia (Sni) 04-6292.2.24-2001 For Safety Equipment
Journal Title: ASIAN JOURNAL OF NATURAL & APPLIED SCIENCES - Year 2014, Vol 3, Issue 4
Abstract
Leakage current testing is one of the types of electrical safety test, where test is intended to determine the level of security of an electronic product in this refrigerator URG - 129. Testing is done by giving some different behavior to the test specimen, ranging from varying the loading rate and the value of the input voltage be changed. To then measured the value of electric current leaking from the installation of ground or body surface of the test specimen. From the analysis of the leakage current values obtained under full load with input voltage of 245 Volts PLN, for earth leakage line ( normal ) ( 2458 ± 0335 ) mA, earth leakage line ( single fault) ( 4.0983 ± 0338 ) mA, Touch Chassis ( single fault ) ( 2.485 ± 0.334 ) am. Based on the value of leakage current, then the refrigerator Uchida URG - 129 is expressed not meet the requirements as specified in ISO 04-6292.2.24-2001.
Authors and Affiliations
Ali Musyafa, Yerri Susatio, Zulkifli , R. Setiyawan
REMOVAL OF CHLOROPHENOL FROM AQUEOUS SOLUTION USING FLUTED PUMPKIN AND COMMERCIAL ACTIVATED CARBON
This work aimed at exploring the potential use of fluted pumpkin stem waste as a biosorbent for the removal of chlorophenol from aqueous solutions. Batch kinetics and isotherm studies were performed to evaluate t...
A STUDY OF REQUIREMENTS VALIDATION WITH UML
he major concern of requirements validation is to evaluate software system at the end of the software development process to ensure compliance with the software requirements. Among the various b...
GOODNESS OF FIT TEST: A CHI-SQUARED APPROACH TO FITTING OF A NORMAL DISTRIBUTION TO THE WEIGHTS OF STUDENTS OF AKWA IBOM STATE UNIVERSITY, NIGERIA
This paper fits a normal probability model to the Weights of Students of the Akwa Ibom State University. A sample of 970 Students was drawn from the Medical Centre of the Institution’s Main Campus, Ikot Akpaden, Akwa Ib...
FAULT DETECTION ON RADIAL POWER DISTRIBUTION SYSTEMS USING FUZZY LOGIC
Electric power distribution systems are expected to function at all times, even under fault conditions. However, When they operate under fault conditions, the system operator receives information which makes it v...
PROCESS CAPABILITY EVALUATION OF SHAPED METAL DEPOSITION INTEGRATED SYSTEM THROUGH CONTROLLING THE DIMENSIONS OF FABRICATED PARTS OF AUSTENITIC STAINLESS STEEL
The aim of this work is to investigate the process capability of the shaped metal deposition processes to be able to fabricate products with geometries meet the required specifications of the designed parts. The intent o...