LIMITATIONS OF CURRENT OF THE THREE-PHASE ACTIVE POWER FILTER IN THE CONDITIONS OF OVERLOAD AND SHORT CIRCUIT

Abstract

Purpose. The purpose of the work is to develop a method of limiting the maximum allowable level of current of a three-phase active power filter in conditions of overload or short circuit and a system for the implementation of the method. Methodology. For research purposes, the provisions of the pq-theory of instantaneous power, the method of the theory of automatic control in systems with relay controllers, and the methods of simulation in the visual programming environment were used. Results. Both the overloading mode and the short circuit emergency mode, using the proposed solution, do not lead to significant changes in the voltage level on the accumulation capacitor, thus maintaining the stability of the power part of the active power filter. Originality. In the case of temporary overloads of current and short circuits at the network node to which a active power filter is connected, the current's limiting is performed by scaling the current to the level allowed by normal operation of the semiconductor elements of the device, which allows the basic operating algorithm to be implemented in the specified modes. Practical value. The proposed solution can be used as a mean to protect the power part of the device in case of overload, which, in the event of emergencies, and their elimination will automatically restore the normal mode of the device.

Authors and Affiliations

R. V. Vlasenko, O. V. Bialobrzeski

Keywords

Related Articles

NUMERICAL SIMULATION OF SPARK DISCHARGE CHARACTERISTICS IN LIQUID NITROGEN

In MHD approximation, a mathematical model of spark discharge in liquid nitrogen is worked out on the basis of data generalization pertaining to thermodynamical functions and mass-transfer coefficients in a wide paramete...

THE LAW OF ELECTROMAGNETIC INDUCTION

Mathematical models of the electromagnetic induction law which do not take into account Faraday’s restrictions are not in full accordance with the physical phenomenon and so they are not laws. Their incomplete correspond...

AUTOMATED CALCULATIONS OF THE DYNAMICS OF TURBOGENERATOR ELECTROMAGNETIC PROCESSES IN SOFTWARE ENVIRONMENT FEMM

Attention is paid to the popular FEMM (Finite Element Method Magnetics) program which is effective in the numerical calculations of the magnetic fields of electrical machines. The principles of the automated calculations...

RESEARCH OF THE APPLICATIONS POSSIBILITY OF INTERFACE RELAY IN HYBRID SWITCHING SYSTEMS OF BISTABLE ACTUATORS WINDINGS

Purpose. Development of methods of experimental determination of action coordination characteristics of semiconductor and mechanical switching elements in systems of hybrid commutation of bistable actuators coils taking...

A CHOICE OF SECTIONS OF ELECTRIC WIRES AND CABLES IN CIRCUITS OF DEVICES OF HIGH-VOLTAGE HIGH-CURRENT IMPULSE TECHNIQUE

Purpose. Implementation of calculation choice of sections of electric wires and cables in circuits of devices of high-voltage high-current impulse technique (HHIT), characterized flowing of pulsed current ip(t) with diff...

Download PDF file
  • EP ID EP483758
  • DOI 10.20998/2074-272X.2018.1.04
  • Views 118
  • Downloads 0

How To Cite

R. V. Vlasenko, O. V. Bialobrzeski (2018). LIMITATIONS OF CURRENT OF THE THREE-PHASE ACTIVE POWER FILTER IN THE CONDITIONS OF OVERLOAD AND SHORT CIRCUIT. Електротехніка і Електромеханіка, 0(1), 29-34. https://europub.co.uk/articles/-A-483758