Low-Voltage Ride-Through Solution for a grid connected DFIG Wind Turbine using Series Voltage Compensation

Abstract

This paper presents a new solution for doubly fed induction generators to stay connected to the grid at the time of faults and sags. To create the required flux to keep the rotor side converter current below its transient rating the stator voltage is increased to certain level at the time of faults. In order to maintain that one we are injecting the required voltage in series to the stator side line by designing a series compensator. The series converter will examine the grid voltages and provides compensation accordingly to keep DFIG to continue its operation. . Since the turbine and converter stay connected, the synchronization of operation remains established during and after the fault and normal operation can be resumed immediately after the fault is cleared. . To keep the current at its minimum, a control strategy has been developed to keep the injected voltage and line voltage in phase during and after the fault. The energy efficiency of wind turbine systems equipped with doubly-fed induction generators are compared to other wind turbine generator systems

Authors and Affiliations

Siva Kumar Ambati

Keywords

Related Articles

Studies on cytotoxic effects of cycloheximide on root meristem of Allium sativum L

The cytotoxic effects of Cycloheximide, a widely used fungicide were investigated on meristematic cells of A. sativum L. The results showed that the fungicide is mitodepressive in nature. It also induced various types of...

A Robust Low Power Security System for Multi-Node Communication

Wireless sensor network (WSN) is a collection of sensors organized into a cooperative network. The sensors are monitor the physical or environmental conditions, such as temperature, sound, pressure, etc. and to cooperati...

Monitering System for Human Activity

Healthcare costs is increase as age increase. The healthcare system is now transfer into system in which continuous monitoring of patient is possible. Without hospitalization continuous monitoring of patients is possible...

Energy Aware 32 Bit Arithmetic and Logical Unit for Error Tolerant Applications

In this era of high end devices, the power efficient architecture is taking responsibility so as to reduce the cost for maintenance. This becomes the critical task for embedded based device, graphical based processor and...

A Multilevel Scoring Segment for Computing Routing Plans

The developing number of datasets distributed on the Web as connected information brings both open doors for high information accessibility of information. As the information builds challenges for questioning additionall...

Download PDF file
  • EP ID EP221139
  • DOI -
  • Views 93
  • Downloads 0

How To Cite

Siva Kumar Ambati (2014). Low-Voltage Ride-Through Solution for a grid connected DFIG Wind Turbine using Series Voltage Compensation. International journal of Emerging Trends in Science and Technology, 1(9), 1520-1531. https://europub.co.uk/articles/-A-221139