Management of Femoral Bone Defect after Gunshot Injury using Circular External Fixator

Journal Title: Journal of Pakistan Orthopaedic Association - Year 2018, Vol 30, Issue 01

Abstract

Objectives: Retrospective evaluation of healing index (HI) and consolidation time (CT) of gunshot femoral bone loss managed using conventional Ilizarov frame (CIF) versus Talyar Spatial Frame (TSF) fixator. Methods: This multicenter study included 15 patients had gunshot femoral bone loss of about 6 cm and average soft tissue defects of about 7 cm. External fixator was used in 9 patients, soft tissue defect was directly closed in 5 patients, using rotational flap in 5 patients, multiple Z-plasty in 2 patients and in 3 patients soft tissue defect was open managed and closed by secondary intention after application of CIF fixator. CIF fixator was used in 8 and TSF fixator in 7 patients. Mean latency period before starting distraction osteogenesis was 12.8±0.8; range: 12-14 days. Results: Mean distraction rate was 1.2±0.3 mm/day and inter-fragmentary compression rate was 0.25 mm/day for 5-7 days. Mean consolidation time was 97.8±18.1 days, and all patients had bone lengthening for a mean of 6.4±1.2 with a mean healing index of 15.3±1.37; range: 13.2-17.3. Patients categorized according to type of fixator showed non-significant (p>0.05) difference as regards clinical data. Conclusion: Distraction osteogenesis for gunshot femoral bone injuries could be achieved successfully using either Ilizarov or TSF circular fixator. Both fixators allowed bone lengthening within reasonable CT and with HI of about 15 days/cm.

Authors and Affiliations

Ibrahim Elsayed Abdellatif Abuomira1, Francesco Sala2, Mahmoud Mabrouk Said3, Ehab A. Abdalla Elshal1,Amar Abdelhalem Amar1

Keywords

Related Articles

A Study to Determine The Type of Knee Injuries Sustained During Assault Course Training in Military Personnel

To present extreme physical activity in military personnel can lead to a torn anterior cruciate ligament. Study design: Retrospective descriptive Study Place and duration of study: Rawalpndi and Multan 9 years peri...

Is distal femoral locking plate the implant of choice to fix all types of Distal femoral fractures?

Objective: To determine the radiological and functional outcome of different types of distal femoral fractures fixed with locking plates. Methods: This descriptive case series study was conducted at Department of Orth...

Comparison of Clinical and Radiological Outcomes of Freehand Patellar Resection Technique Versus Cutting Guide Technique in Total Knee Arthroplasty.

Objective: To compare the clinical and radiological outcomes of freehand patellar resection technique versus cutting guide technique in primary total knee arthroplasty. Methods: This randomized controlled trial was cond...

Traumatic Brachial Plexus Injuries: HULS Protocol of Management.

Objective:To determine the functional outcome of traumatic brachial plexus injuries managed in our institution with our own designated treatment protocol( Hand and Upper Limb Surgery-HULS). Methods:This descriptive st...

Early Hip Spica Cast Application in Treatment of Femoral Shaft Fracture in Children

To determine the efficacy of early hip spica cast application for the management of femur shaft fractures in children. Material and Methods: This descriptive study was carried out in the Department of Orthopaedic Surg...

Download PDF file
  • EP ID EP741715
  • DOI -
  • Views 20
  • Downloads 0

How To Cite

Ibrahim Elsayed Abdellatif Abuomira1, Francesco Sala2, Mahmoud Mabrouk Said3, Ehab A. Abdalla Elshal1, Amar Abdelhalem Amar1 (2018). Management of Femoral Bone Defect after Gunshot Injury using Circular External Fixator. Journal of Pakistan Orthopaedic Association, 30(01), -. https://europub.co.uk/articles/-A-741715