Management of lateral end clavicle fractures using clavicle hook plate vs lateral clavicle locking plate: A comparative study
Journal Title: Medpulse International Journal of Orthopedics - Year 2019, Vol 9, Issue 2
Abstract
Background: The study was conducted to compare the functional outcome of clavicular hook plate and lateral clavicle locking plate for displaced lateral end clavicle fractures using Constant Murley score. Materials and methods: This study include total of 30 cases with displaced lateral end clavicle fractures satisfying the inclusion criteria treated with lateral clavicle locking plate (15cases) and clavicle hook plate (15 cases). Patients were followed up at 1st month, 2nd month and 6th month, the functional outcome was assessed using Constant Murley score and the radiological outcome was also assessed. Results: In our study, 15 cases treated with clavicle hook plate had better results than 15 cases treated by lateral clavicle locking plate in terms of fracture union, Constant Murley score, range of movements. At the final follow-up of 6 months, excellent outcome was seen in 26.7% of patients treated with hook plate as compared to 6.7% of patients treated with lateral clavicle locking plate. Conclusion: Both hook plate and locking plate have a good functional outcome for lateral end clavicle fractures. Addressing the coracoclavicular ligaments in case of lateral locking plate is of utmost importance in comminuted lateral end clavicle fractures. Hook plate is an absolute indication for comminuted lateral end clavicle fractures. Hook plate has implant-related complications, hence implant removal at earliest is advisable.
Authors and Affiliations
Sujana Theja J S, B Gurumurthy, Pavankumar Patted
Treatment of aseptic nonunion of tibia study of 35 cases by ilizarov ring fixator: A prospective clinical study
Objective: To achieve union at nonunion site with correction of limb length discrepancy and correction of deformity with early function and mobilization. Methods: It is prospective study of treatment of aseptic nonunion...
Management of intertrochantric fractures with dynamic hip screw and trochanteric femoral nail - A prospective comparative study
Background: Intertrochanteric hip fractures account for approximately half of the hip fractures in the elderly and pose a number of management dilemmas depending on the fracture configuration and status of the bones. A w...
Functional outcome of arthroscopic reconstruction of anterior cruciate ligament injuries using quadrupled semitendinosus graft
Background: A wide variety of techniques and graft types are now available for the reconstruction of ACL. Arthroscopic ACL reconstruction using quadrupled semitendinosus tendon autograft with fixation in the femoral tunn...
Shaft Humerus Fractures Treated with Interlocking Nails Vs Dynamic Compression Plate - A Comparative Study
Background: Fractures of shaft humerus are very common. This study was conducted to assess the outcome of this fracture by two most common mode of treatment that is open reduction internal fixation with DCP and Close Hum...
Outcome evaluation of subtrochanteric femur fractures treated with proximal femoral nails
Background: Subtrochanteric femur fractures have demanded special consideration in orthopaedic traumatology, given the high rate of complications associated with their management. The proximal femoral nails were develope...