Mechanical Behavior of Urban Rail Transit Station Structure Based on Existing Shield Tunnel Interval Underground Excavation Construction

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 8

Abstract

Objective Cancer Hospital Station on Shenzhen Rail Transit Line 14 adopts a scheme of large-diameter (8.5 m) shield tunnel expansion featuring tunnel-first and station-later. During the connection of the main station structure and auxiliary entrances in underground excavation, the construction of large local openings in tunnel lining is required. To ensure the structural safety during tunnel opening construction, it is necessary to study the mechanical behavior of urban rail transit station structure based on existing shield tunnel interval underground excavation. Method To simulate the station underground excavation process under various working conditions, a multi-ring shell-rigid beam-contact lining calculation model considering the effects of lining structure circumferential and longitudinal joints is adopted. The scenarios include full-opening lining ring control condition (opening condition) and half-opening lining ring control condition (support removal condition). Key design parameters, such as the position of capping block, the forms of internal support, and the dimension of tunnel longitudinal opening, are analyzed for their impact on station structure. Result & Conclusion Based on the stress characteristics of ring beams, it is recommended to use steel or embedded steel components for the upper and lower ring beams in the design. It is recommended that the arrangement of through-joint assembled segments in the opening area should be adopted according to segment stress characteristics, and the capping block of tunnel opening section through-joint assembled segments be designed at the tunnel top for Cancer Hospital Station. The bending moment distribution of opening lining ring segments throughout construction process is closely related to the effective constraint points of internal supports, and the premise of internal supports forming effective constraint is a complete axial force transmission path. The integrity of opening lining ring structure is contingent upon the lateral constraints of circumferential joints during the local tunnel opening construction.

Authors and Affiliations

Zhongan ZHANG, Ye PAN, Zhenkun GUO, Jiaolong ZHANG, Yimin GAO, Xian LIU

Keywords

Related Articles

New Method for Metro Tunnel Catenary Height Detection Based on Mobile 3D Laser Scanning Technology

[Objective] The height of metro tunnel catenary is a crucial parameter for ensuring normal train electrification and requires regular inspection. In response to the significant errors and low precision associated with ot...

Shanghai Rail Transit Integration Development Strategy Based on Yangtze River Delta Integration

[Objective] With the deepening integration of regional development, it is essential to enhance the service level of urban rail transit, alleviate transportation pressure, and integrate regional resources. To achieve inte...

Optimization Design of Metro Vehicle Air Compressor Frame Structure Based on Adaptive Response Surface Method

Objective A finite element model of metro vehicle air compressor frame is established and verified through modal testing and vibration testing. It is found that the vertical bending modal frequency of the dryer frame coi...

Flood Prevention System Construction and Innovative Equipment Application in Metro Engineering

Objective In recent years, extreme rainfall weather frequently causes urban flooding, leading to many cases of metro engineering project water disasters, significant economic losses and personnel casualties. It is essent...

Research and Application of Train Communication Network Based on Time-sensitive Networking

Objective TCN (train communication networks) has complex topologies and requires high real-time transmission capabilities. Currently, train data transmission mainly relies on TRDP (train real-time data protocol) for carr...

Download PDF file
  • EP ID EP742694
  • DOI 10.16037/j.1007-869x.2024.08.023
  • Views 15
  • Downloads 0

How To Cite

Zhongan ZHANG, Ye PAN, Zhenkun GUO, Jiaolong ZHANG, Yimin GAO, Xian LIU (2024). Mechanical Behavior of Urban Rail Transit Station Structure Based on Existing Shield Tunnel Interval Underground Excavation Construction. Urban Mass Transit, 27(8), -. https://europub.co.uk/articles/-A-742694