Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna

Journal Title: Journal of Musculoskeletal Disorders and Treatment - Year 2016, Vol 2, Issue 3

Abstract

The purpose of the study was to test the mechanical fatigue properties (fatigue limit and fatigue strength) of two locking plates designed for the distal ulna. Distal Ulna Plate 2.5 (Medartis, Basel, Switzerland) and 2.0 mm LCP Distal Ulna Plate (DePuySynthes, West Chester (PA), USA) were used. A metaphyseal fracture situation was chosen (AO 23-A1.3). Six plate-screw constructs of each design were mounted on custom made fixtures using a Sawbone's 3D ulna model. Testing was performed on monoaxial material testing machines. Endpoints were fatigue strength (load) and fatigue limit (cycles) when the sample fails. Initial load was set at Fmax 10 N. Sinusoidal loading was carried out at 4 Hz. After 50'000 cycles load was increased by 15% and again by 15% after each additional 10'000 cycles. 2.5 mm plates showed median fatigue strength of 40.5 N (range 5.3) and median fatigue limit of 141'307 cycles (range 5'436). 2.0 mm plates 13.2 N (range 5.2) and 67'287 cycles (range 28'718) respectively. Distal Ulna Plate 2.5 showed better mechanical properties.

Authors and Affiliations

Keywords

Related Articles

Phoenix Project for Improving the Quality of Life in Rheumatic Diseases: Preliminay Results

Rheumatic chronic diseases (RCD) are among the most common chronic non-communicable diseases. They are the leading cause of disability in developed countries, and consume a large amount of health and social resources. T...

Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna

The purpose of the study was to test the mechanical fatigue properties (fatigue limit and fatigue strength) of two locking plates designed for the distal ulna. Distal Ulna Plate 2.5 (Medartis, Basel, Switzerland) and 2.0...

Molecular Changes at the Post-Synapse and Improved Motor Function Suggest Accelerated Recovery with SARM Treatment in an Androgen-Depleted Animal Model of Nerve Injury

Nerve crush injury at focal sites causes rapid muscle atrophy in the connected muscle downstream of the affected motor end plate, and results in profound functional and metabolic deficits. This report characterizes the r...

Medial Epicondylitis and Medial Elbow Pain Syndrome: Current Treatment Strategies

Medial elbow pain is a common complaint in the active population. The most frequent muscular or tendinous condition to cause medial elbow pain is Medial Epicondylitis (ME). The disorder is classically described as "Golfe...

Necrotizing Fasciitis without Inflammatory Signs in Patients Receiving Anti-Interleukin-6 Receptor Antibody (Tocilizumab): Two Cases Report

Tocilizumab is a monoclonal antibody directed against the interleukin-6 receptor and used for the treatment of rheumatoid arthritis (RA). However, patients treated with tocilizumab have risk of infection, such as necroti...

Download PDF file
  • EP ID EP348042
  • DOI 10.23937/2572-3243.1510018
  • Views 126
  • Downloads 0

How To Cite

(2016). Mechanical Fatigue Analysis Comparing Two Locking Plates in a Metaphyseal Fracture Model of the Distal Ulna. Journal of Musculoskeletal Disorders and Treatment, 2(3), 1-4. https://europub.co.uk/articles/-A-348042