MEDICATION DISPENSING ERRORS IN URBAN PHARMACIES: IMPLEMENTING BARCODE TECHNOLOGY

Journal Title: Acta HealthMedica - Year 2017, Vol 2, Issue 1

Abstract

Introduction: The importance of patient safety has drawn attention to reducing and preventing medication errors, which can lead to increased effort in using information technology systems. Using barcode technology in the pharmacy could reduce dispensing errors, but data about its effect are limited. The aim of this study was to evaluate the frequency of medication dispensing errors in pharmacies, which are equipped/nonequipped with barcode scanning systems. Methods: This research was a prospective and quasi-experimental “post-intervention with equivalent control group” study carried out in two community pharmacies in Mashhad, Iran, from January to February 2015. In a pharmacy, a barcode scanning system was used for recognizing medication (Pharmacy A), while such a system was not used in the other one (Pharmacy B). The study population consisted of all the received prescriptions in both pharmacies during a period of two months. The number of relevant transcription, prescription filling and pharmacist action errors (wrong strength, wrong dispensing form, wrong medicine, wrong quantity, omission errors) were assessed. The traveled distance for preparing prescriptions and patient waiting time also were considered as outcomes. Results: A total of 2386 and 900 paper prescriptions were received by the Pharmacy A and Pharmacy B, respectively. There were 211 (7/7%) dispensing errors in Pharmacy A and 113 (10%) dispensing errors in the Pharmacy B (p<0/05). In Pharmacy A, most error or deficiencies in all prescriptions were found in quantity (4.44%) followed by medicine (2.26%), strength (1.09%), omission (0.67%), and dispensing form (0.38%). In Pharmacy B, the frequencies of the errors in all prescriptions vary in the same order, ranging from 5.78% for the wrong quantity, to 4.89% for the wrong medicine, to 1.78% for wrong strength, and to 0.11% for the wrong dispensing form. No case with omission error was found in Pharmacy B. There were statistical significant differences between the two pharmacies in terms of “wrong medicine” and “omission error” (p<0.05). The percentage of transcription, prescription filling, and pharmacist action errors in proportion of all prescriptions of Pharmacy A were calculated at 3.81%, 4.86%, and 0.17% and in Pharmacy B 6.67%, 5.56%, and 0.33%, respectively (p=0.005, p=0.418, p=0.385, respectively). The error rates related to medicine were detected at 12.9% in Pharmacy A and 30% in Pharmacy B (p=0.013). The traveled distance per each medicine item during the prescription-filling process was 4.4 and 1.5 m in Pharmacy A and B, respectively. Conclusion: Using a barcode scanning system in a pharmacy did not remove all medication errors, but it was associated with reduction of dispensing errors and could improve patient safety

Authors and Affiliations

Mohsen Masoumi, Mohammad Reza Hasibian, Hasan Vakili-Arki, Zhila Taherzadeh, Ehsan Nabovati, Naser Vahdati Mashhadian, Saeid Eslami

Keywords

Related Articles

PREVALENCE OF ASYMPTOMATIC AVASCULAR NECROSIS OF THE HIP IN PATIENTS WITH KIDNEY TRANSPLANTATION

Introduction: Kidney transplant is one of the treatments in patients with ESRD (end stage renal disease) that increases the quality of life in patients. Following kidney transplant, patients need glucocorticoid and immun...

PERSIAN REGISTRY OF CARDIOVASCULAR DISEASE (PROVE)

Introduction: The Persian Registry Of cardioVascular diseasE (PROVE) aimed to study the demographic, clinical, diagnosis and treatment of patients with cardiovascular disease (CVD) and to follow them for 1 to 3 years, l...

THE IMPACT OF PACS (PICTURE ARCHIVING AND COMMUNICATION SYSTEM) ON HOSPITAL WORKFLOW: A SYSTEMATIC REVIEW

Introduction: Today, PACS is used as a digital system for storing, disseminating, management, and presentation of medical images in health care settings. An emerging new digital system can influence users’ workflow. Howe...

MINIMUM DATA SET FOR CYSTIC FIBROSIS REGISTRY: A CASE STUDY IN NORTHWEST IRAN

Introduction: Over the last 25 years, several national registries of CF have been set up. Such systems can be very useful in providing an integrated resource for improving patient care and conducting research on the dise...

THE EFFECTS OF FEEDBACK-BASED INTERVENTION IN ERRORS DUE TO INAPPROPRIATE STORAGE AND TRANSPORTATION OF BLOOD BAGS IN HOSPITAL

Introduction: Storage and transportation of red blood cells (RBCs) outside the standard range temperature as defined by guidelines can lead to hemolysis. One of the main factors believed to cause hemolysis is temperature...

Download PDF file
  • EP ID EP351345
  • DOI 10.19082/ah159
  • Views 135
  • Downloads 0

How To Cite

Mohsen Masoumi, Mohammad Reza Hasibian, Hasan Vakili-Arki, Zhila Taherzadeh, Ehsan Nabovati, Naser Vahdati Mashhadian, Saeid Eslami (2017). MEDICATION DISPENSING ERRORS IN URBAN PHARMACIES: IMPLEMENTING BARCODE TECHNOLOGY. Acta HealthMedica, 2(1), 159-160. https://europub.co.uk/articles/-A-351345