Method for determining the quality of cable inlets sealant using infrared thermography

Journal Title: Вестник МГТУ - Year 2018, Vol 21, Issue 4

Abstract

The results of applying the quality control method to cable inlets sealant (hermetic lead, sealed lead-in, cable boxes) have been considered. Cable inlets are designed to prevent the spread of fire in adjacent areas through cable sealing boxes, e. g. on sea vessels. The known methods for determining the quality of cable inlets sealant are laborious and in some cases even impossible to implement when used on sea vessels. This applies to cases when the room through which the cables pass is being poured with water and some pressure stipulated by the ship specifications is being created there, or when the air pressure increases in such rooms. The novelty of the present method lies in the fact that it is based on the principles of pulsed thermal non-destructive testing of a material. The FLUKE thermovision camera Ti400 has been used as a technical means recording the temperature field of the sealant surface after exposure to a thermal pulse. The method approbation has indicated that thermal non-destructive testing can be used to detect relatively small penetration defects in the sealant volume.

Authors and Affiliations

A. B. Vlasov

Keywords

Related Articles

Chocolate as a product for functional nutrition

The problem of producting food products with functional properties has become increasingly urgent in the recent years. This is explained by the deterioration of the overall ecological situation, the decline in the qualit...

Technology of flour confectionery products using emulsion obtained in conditions of cavitation processing

The idea of using the cavitation energy in food industry appeared in the middle of the last century, but due to absence of efficient machineries and developed process theory this method was not used. The attractiveness o...

Change of physical activity of the grey seal when exposed to the magnetic field with frequencies of 2, 18 and 36 Hz for 1–4 hours

The results of studies of motor activity of the grey seal when exposed to magnetic fields with frequencies equal to 2, 18 and 36 Hz for 1–4 hours have been presented. The data have been obtained using the methods of cont...

Comparative analysis of the quality of drinking tap water in some areas of the Murmansk region

The present work describes the microbiological research of drinking tap water quality of some settlements in the Murmansk region. The samples of drinking tap water have been selected and the microbiological indicators of...

The inclusion of grothite in the zircon from granitoids of the crystalline basement of the Southern Yamal Peninsula

Grothite – rare F-Al-rich type of titanite – has been found in accessory zircon from the granitoids of the pre-Jurassic basement of the Verkhnerechensky oil-gas area (in the southern part of the Yamal Peninsula) as a res...

Download PDF file
  • EP ID EP435429
  • DOI 10.21443/1560-9278-2018-21-4-632-637
  • Views 118
  • Downloads 0

How To Cite

A. B. Vlasov (2018). Method for determining the quality of cable inlets sealant using infrared thermography. Вестник МГТУ, 21(4), 632-637. https://europub.co.uk/articles/-A-435429