METROLOGICAL EVALUATION OF MEASUREMENT SYSTEM FOR TWO-PHASE FLOW FRACTIONS DETERMINATION USING 3D ELECTRICAL CAPACITANCE TOMOGRAPHY
Journal Title: Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska - Year 2013, Vol 3, Issue 3
Abstract
The industrial diagnostic and monitoring systems require new methods offering the possibility of non-invasive observation and analysis of the two-phase gas-liquid mixtures flows. The designed new measurement system is dedicated for non-invasive percentage phase distribution calculation and flow structure identification in the vertical and horizontal pipelines. This paper presents some research results of the metrological validation of the designed three-dimensional capacitance tomography measurement system including: the 3D ECT sensor structure optimization, the metrological analysis of the image reconstruction process accuracy and the metrological analysis of the results of the phase distribution calculation method in comparison with other common technics. As a result of performed analysis the height capability of the 3D ECT measurement system for non-invasive real time dynamic flow processes identification was proved.
Authors and Affiliations
Radosław Wajman, Henryk Fidos, Paweł Fiderek, Tomasz Jaworski, Jacek Nowakowski, Dominik Sankowski, Robert Banasiak
DIRECT TORQUE CONTROL OF MULTI-PHASE INDUCTION MOTOR WITH FUZZY LOGIC SPEED CONTROLLER
The paper presents the Direct Torque Control with Space Vector Modulation (DTC-SVM) of seven-phase induction motor with Fuzzy Logic Speed Controller. The mathematical model of the seven-phase squirrel-cage induction moto...
ENSURING THE STABILITY OF CONTACT MEASUREMENTS IN AUTOMATED CONTROL SYSTEMS FOR PRECISION GRINDING
Control the size of the parts in the process of their processing on the grinding machine is performed using the measuring heads with a special equipment that mechanically is in contact with the surface of the control. Th...
BENCHMARKING W ELEKTROENERGETYCZNYCH SYSTEMACH DYSTRYBUCYJNYCH
Artykuł prezentuje analizę stosowanych wskaźników niezawodności zasilania w strukturach elektroenergetycznych Polski i Europy,w kontekście benchmarkingu na poziomie funkcjonalnym i operacyjnym, której celem jest wskazani...
EFFECT OF HIGH VOLTAGE ON THE DEVELOPMENT OF THE PLANT TISSUE
In our experiment the electrical parameters that affect early somatic embryos (ESEs) were investigated. High voltage was generated by a special high voltage generator. High voltages ranging from 5 to 20 kV and frequency...
A DISTRIBUTED METHOD FOR TRANSIENT SIMULATIONS THAT DYNAMICALLY CONSIDERS SUPPLEMENTARY RESULTS FROM AUTONOMOUS SOFTWARE AGENTS
Based on autonomous software agents capable of calculating individual numerical field problems, a distributed method for solving transient field problems is presented. The software agents are running on distributed resou...