Microgap Evaluation of Novel Hydrophilic and Hydrophobic Obturating System: A Scanning Electron Microscope Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 5

Abstract

Introduction: The purpose of an endodontic obturation is to obtain a fluid tight hermetic seal of the entire root canal system. There has been an evolution of different materials and techniques to achieve this desired gap free fluid tight seal due to presence of anatomic complexity of the root canal system. Aim: To compare the microgap occurring in root canals obturated with hydrophilic versus hydrophobic systems using scanning electron microscope. Materials and Methods: Sixty extracted human single-rooted premolars were decoronated, instrumented using NiTi rotary instruments. The samples (n=20) were divided into three groups and obturated with Group A - (control group) gutta-percha with AH Plus, Group B - C-point with Smartpaste Bio and Group C - gutta-percha with guttaflow 2. The samples were split longitudinally into two halves and microgap was observed under scanning electron microscope in the apical 3 mm of the root canal. Results: Group A (control) showed a mean difference of 8.54 as compared to 5.76 in group C. Group B showed the lowest mean difference of 0.83 suggesting that the hydrophilic system (C-point/Smartpaste Bio) produced least microgap as compared to the hydrophobic groups. Conclusion: Novel hydrophilic obturating system (C-points/ Smart-paste Bio) showed better seal and least microgap as compared to gutta-percha/guttaflow 2 and gutta-percha/ AH plus which showed gap at the sealer dentin interface due to less penetration and bonding of these hydrophobic obturating system.

Authors and Affiliations

Vibha Hegde, Laxmi Suresh Murkey

Keywords

Related Articles

Rare Presentation of Primary GI Lymphoma with Synchronous Lesions in a Retropositive Patient

ABSTRACT Non Hodgkin’s Lymphoma (NHL) with primary Gastrointestinal (GI) involvement occurs in 27-74% of all HIV infected persons. Most common site of involvement is stomach, small intestine and ileocaecal region. Synchr...

Teaching and Assessing Reflecting Skills among Undergraduate Medical Students Experiencing Research

Introduction: Reflection is the integral component of lifelong learning. Hence, there is a need for incorporating opportunities for students in the curriculum, to develop these skills. Aim: To evaluate the feasibility of...

Evaluation of the Potency of Kinetin on Radiation Induced Behavioural Changes in Swiss Albino Mice

Introduction: According to the various independent studies conducted, it is well evident fact that radiation induces oxidative stress in the living system. It is also proved that this oxidative stress will lead to the va...

Neglected Type I Monteggia Fracture Dislocation in Adult

Neglected Monteggia fracture dislocation is one of the challenging case and it becomes more of a therapeutic dilemma especially in adults. Several surgical techniques are described and in spite of this complication rate...

Effectiveness of Formative Assessment in Motivating and Improving the Outcome of Summative Assessment in Pharmacology for Medical Undergraduates

ABSTRACT Introduction: Assessment is a basic component of teaching and learning. Formative assessment (FA) with timely comprehensive feedback can prepare the students to be good learners. Aim: To understand the role of F...

Download PDF file
  • EP ID EP347132
  • DOI 10.7860/JCDR/2017/27458.9923
  • Views 78
  • Downloads 0

How To Cite

Vibha Hegde, Laxmi Suresh Murkey (2017). Microgap Evaluation of Novel Hydrophilic and Hydrophobic Obturating System: A Scanning Electron Microscope Study. Journal of Clinical and Diagnostic Research, 11(5), 75-78. https://europub.co.uk/articles/-A-347132