Mitigation of commutation faults in HVDC system

Journal Title: International Journal of Engineering and Science Invention - Year 2017, Vol 6, Issue 10

Abstract

To transfer large amount of direct current power having high amplitude voltage over long distance, high voltage direct current (HVDC) transmission system is used. This system was introduced 60 year ago and now it is widely used all over the world. Some examples of HVDC systems are following; Voltage-SourcedConverter (VSC), current commutated converter (CCC) and line commutated converter (LCC) dependent HVDC techniques.VSC method used for multi-terminal Direct Current grid, but line commutated direct current method performs better as compare to VSC in broad distance large amount of power transmission due to its efficiency. When voltage is reduced to 10% to 15% in LCC HVDC system the commutation failure occurs. The LCC HVDC system is having better performance in comparison to others so the analysis is done on this system to mitigate the commutation failure which is very frequent event that occurs in the this system. The DC fault is having less effect on commutation as compare to the AC single and three phase fault. During DC fault only the distortion is occurring which is minimized with the help of DC filter. During AC faults the commutation failure occurs which is minimized using IGBT capacitor circuit. The comparison of systems with and without faults is done and it is concluded that the AC faults are the main reason of commutation failure and mitigation is done using IGBT capacitor circuit.

Authors and Affiliations

Kamaljeet Kaur, Navneet Singh Bhangu

Keywords

Related Articles

Service Cloud Implementation on Salesforce.Com Platform.

Salesforce.com is innovative company behind the world’s #1 CRM platform that employees can access entirely over the Internet there’s no infrastructure to buy, set up, or manage you just log in and get to work. And now ou...

An Overview of Fuzzy Logic Applications

Fuzzy logic has become a very promising mathematical approach that is based near the human thinking and natural activities. In a classical logic system an object either is or is not a member of a set but a member in a fu...

Screening for antimicrobial activity of some medicinal plants.

During present study the antibacterial activity of the petroleum ether extracts of Vitex negundo, Duranta repens, Piper nigrum and Acorus calamus were analysed. The antibacterial potential of these extracts were tested o...

Performance of Steel Bracings on Seismic Response In R.C Framed Structures

The A Reinforced Concrete Building Should Be Designed To Have A Capacity To Carry Combined Loads (Dead, Live And Seismic Loads) At Certain Safety Level And At Certain Degree Of Reliability. Proper Account Of Loads, Mater...

Experimental Investigation on Partial Replacementof Coarse Aggregateby Recycled Aggregatein Concrete

Aggregate resulting from the processing of inorganic material which are previously used in the construction is known as recycled Aggregates. Nowadays using the Waste materials is a global trend. In the fieldof constructi...

Download PDF file
  • EP ID EP403429
  • DOI -
  • Views 70
  • Downloads 0

How To Cite

Kamaljeet Kaur, Navneet Singh Bhangu (2017). Mitigation of commutation faults in HVDC system. International Journal of Engineering and Science Invention, 6(10), 79-88. https://europub.co.uk/articles/-A-403429