In three single phase high voltage underground cable induce voltages and currents in their sheaths. The sheath induced currents are undesirable and generate power losses and reduce the cable ampacity whereas the induced voltages can generate electric shocks to the workers that keep the power line. This means that when dealing with three single phase high voltage underground cable, it is very important to know the sheath currents called circulating currents that can circulate throughout the sheath and sheath voltage of the cables. It is very useful to know their values and the technique to reduce the sheath voltage of the high voltage Cable. This study presents as technique known as Mixed bonding technique combination of cross bonding and single point bonding to reduce the sheath voltage of the long length cable route. Manish Kumar | Ameen Uddin Ahmad"Mixed Bonding Method of High Voltage Cable" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-1 | Issue-5 , August 2017, URL: http://www.ijtsrd.com/papers/ijtsrd2348.pdf http://www.ijtsrd.com/engineering/electrical-engineering/2348/mixed-bonding-method-of-high-voltage-cable/manish-kumar

Authors and Affiliations

Keywords

Related Articles

A Clinical Study on Vrisha Gritha Aschyothana and Paana in the Management of Prathamapatalagata Timira

Forty diagnosed cases of Prathama Patalagata Timira Simple myopia were and registered for clinical study irrespective of gender, socioeconomic status and religion with an aim to know the efficacy of Vrisha Gritha Aschyot...

Minority Rights Development Needed

This paper trying to discuss in detail the concept of minorities and the problem of absence of an appropriate and largely accepted definition and how it is high time that these minorities needed to be protected by their...

Design and Performance Analysis of a LCD Laboratory Lantern

This paper presents the performance of a LCD laboratory lantern designed to combust varieties of biofuels. The burner was designed as a laboratory scale standard model for experimental purposes. The effect of biofuel ato...

The Deep Rooted Gender Biasness in Section 375: Analysis

In this research paper the researcher basically deals with the Section 375 of the Indian Penal Code,1860. The researcher aims at analyzing this section in detail. The researcher will be dealing with meaning as well as th...

Microbial Status and Identification with Antibiotic Susceptibility Patterns of Enteric Pathogen Escherichia Coli and Vibrio Cholerae Isolated from Different Street Foods Sold in Dhaka City, Bangladesh

There are various benefits offered by street vended foods, but street foods are contaminated with many foodborne pathogens includes enteric pathogenic bacteria like Escherichia coli and Vibrio cholerae has become a poten...

Download PDF file
  • EP ID EP358078
  • DOI -
  • Views 134
  • Downloads 0

How To Cite

(2017). Mixed Bonding Method of High Voltage Cable. International Journal of Trend in Scientific Research and Development, 1(5), -. https://europub.co.uk/articles/-A-358078