Modeling and Torque Ripple Control in Faulty SPMSM
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2016, Vol 40, Issue 40
Abstract
This paper presents a model of a Surface Permanent Magnet Synchronous Motor which can be used in a faulty case and a torque ripple control approach developed to be applied if the faulty case is detected. Two faulty cases are considered for study, the first consider an asymmetry between the stator phases of the motor created by unbalanced number of turns and the second a short circuit between the stator windings of the motor. Proposed torque ripple control use a phasor approach to provides the current reference for stator asymmetry and an injection of an inverse current for stator short circuit fault in order to decrease the motor torque ripple. The torque control has been implemented using a model of surface permanent magnet synchronous motor based on the dynamic equations. Simulation and experimental results highlight the link between the faulty and the torque ripple and show the possibility to decrease in this case the torque ripples by changing a balanced sinusoidal current reference by unbalanced one. In practical tests the impact of the unbalanced system of currents in the torque variation is studied using an analysis of vibratory harmonic measured at twice of the supply frequency.
Authors and Affiliations
Elmehdi Bahri, Remus Pusca, Raphael Romary, Driss Belkhayat
THERMAL AGEING OF OIL IMPREGNATED PAPER FOR POWER TRANSFORMERS INSULATION SYSTEMS
The assessment of conditions and life time reserves of power transformers is generally done based on the analysis of characteristics of main components of insulation systems (oil and paper). During operation, the insula...
ON THE AMPACITY OF INSULATED CONDUCTORS IN CONDUIT
In the paper, a practical method for determining the smallest allowable cross-sectional area of circuit insulated conductors or single-core cables in conduit buried in a thermally insulated wall is proposed. A way to obt...
The Online Temperature Control
In this paper is presented the hardware and software design of a remote controlled system which can have multiple destinations. In particularly, this system is used to create an online thermostat using a microcont...
Study of Indirect Current Control Methods for Urban Traction Active DC Substations
Although the high power DC traction substations are using 12 pulse rectifier which have lower distortion than the classical 6 pulse rectifier, considering the high power, the reactive and harmonic components of the...
Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users
The reactive power flows affect voltages, losses and transmission capacities. Thus MVAR flows are a matter of increasing concern for the grid operators and the Romanian Regulatory Authority for Energy has established the...