A COMPARISON OF Ni-Ti ROTARY AND HAND FILES INSTRUMENTATION IN PRIMARY MOLARS

Journal Title: Journal of International Dental and Medical Research - Year 2013, Vol 6, Issue 1

Abstract

 The aim of the study was to compare the manual and rotary endodontic instruments focusing on risk of perforation when the whole root canal length is instrumented as well as the time required for preparation in primary teeth Fifty four teeth were divided randomly into three groups.Group I: The root canals were prepared manually with K-files. Group II : ProTaper instruments were used in a crown-down manner, Group III: The root canals was prepared with the Hero 642 system. The perforations were made by Hero 642 was %22 and there was no significant differences between groups (P>0.05). Also there was no significant differences between primary maxillary and mandibular teeth (P>0.05) according to perforations.For maxillary and mandibular teeth, the longest time shaping time was recorded when manual technique was used (p<0.05). Also, no statistically difference was found between ProTaper and Hero 642 according to time. Finally, there was statistically significant difference between rotary and manuel techniques for time of instrumentation (p<0.05). Care must be taken with each rotary file, for overpreparation can lead to unexpected lateral perforation, especially in severely curved canals. Rotary preparation for primary teeth was faster than hand preparation and this is very important for shorten the chairtime in pediatric dentistry.

Authors and Affiliations

Bugra Ozen, Ozlem Akgun

Keywords

Related Articles

 SIGNS AND SYMPTOMS OF POSTOPERATIVE COMPLICATIONS IN THIRD MOLAR SURGERY

 Third molar surgery (TMS) is not free from complications. However, there is no hierarchy, definition or critical appraisal of all clinical manifestations related to these complications. The purpose of this articl...

  COMPARATIVE EVALUATION OF DIAMETRAL TENSILE STRENGTH OF PHOSPHATE BONDED INVESTMENT MATERIALS AFTER DRYING BY VARIOUS METHODS”–AN INVITRO STUDY

 The study is to evaluate and compare the Diametral Tensile strength of Phosphate bonded Investment materials (Wirovest, Cromocasting Fast and Accuvest) after drying by Air dried method, Conventional Hot air ov...

NEW DIRECTION FOR MEASUREMENT OF MICROLEAKAGE IN CARIOLOGY RESEARCH

The present study introduces the feasibility of a different new direction to determining the microleakage volume associated with dental restorations and the relative marginal adaptation deficiency of teeth in in vitro co...

ESTHETIC FAILURES IN FIXED PARTIAL DENTURES

Esthetic dentistry encompasses those procedures designed to enhance and improve form and appearance of the maxillofacial region. Esthetic dentistry procedures are performed on both hard and soft tissue to correct either...

EVALUATION OF THE PLAQUE REMOVING ABILITY OF CONVENTIONAL AND CURVED BRISTLE TOOTHBRUSH IN PEDIATRIC PATIENTS

The aim of this study was to determine the plaque-removing ability of curved bristle toothbrush compared to conventional, straight bristle, toothbrush The study group consisted of 100 children 12 to 16 years of age. A...

Download PDF file
  • EP ID EP120706
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Bugra Ozen, Ozlem Akgun (2013).  A COMPARISON OF Ni-Ti ROTARY AND HAND FILES INSTRUMENTATION IN PRIMARY MOLARS. Journal of International Dental and Medical Research, 6(1), 6-8. https://europub.co.uk/articles/-A-120706