About the Analytical Methods Applying for Fault Diagnosis of the Static Converters from the Electric Locomotive

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2015, Vol 39, Issue 39

Abstract

 In this paper, the results of the monitoring and diagnosis system based on the analytical methods of the auxiliary ventilation service of the electric locomotive which is supplied from the static converter are presented. Because of the complexity of the electric locomotive structure and of the big number of components, a large number of the parameters must be monitored and detected the range of variation of their imposed values. Consequently, a large variety of monitoring and diagnosis procedures have been developed. In literature in the field, the many advanced fault diagnosis methods were presented. Using the analytical method, the analytical model of the static converter was developed using the Matlab Simulink. Starting from the model of the static converter, three types of the faults were simulated: losing inverter supply, interrupting of the inverter output phase and biphasic shortcircuit at inverter output. For all three types of mentioned faults, the waveforms of motor speed, electromagnetic torque and electric currents have been registered. These waveforms were compared with those corresponding to the normal operation regime. The impact of the type of fault on the waveforms was pointed out. The results were analyzed based on the evolution of the motor parameters in the normal and abnormal operating regime.

Authors and Affiliations

Maria Brojboiu, Virginia Ivanov, Andrei Savescu

Keywords

Related Articles

Analysis of Direct Current Motors in Dynamic Regimes Using Numerical Techniques

The electromechanical converters and the electric drive systems where they are parts are generally nonlinear systems due to the nonlinear properties of the materials they are built from, as well as the multiple dependenc...

An Analysis on Efficiency of Wireless Transfer Energy Due to a Misalignment of Two Coils

Function of the alignment of the two magnetic coupled coils, a procedure, to choose the proper structure of the two coils used in the wireless power transfer systems (WPTS’s), is presented. The deviation in the alignment...

 Study of Low Power Alternating Current Motors by Functional and Energy Aspect

 The objectives followed in the frame of this paper are to approach comparatively the two types of motors, from the view point of operation performances and of exploitation expenses obtained with them (asynchronous...

STUDY OF THE DC VOLTAGE CIRCUIT BREAKERS COMMUTATION WITH EMTPWORKS SOFTWARE SIMULATIONS

DC voltage circuit breakers, initially intended for protecting and disconnecting the rectifiers (AC/DC converters), have a wide using in high voltage systems. This paper presents the results of turn-off LC circuit simula...

Hysteresis Current Control of the Single - Phase Active Filter

To compensate harmonic current components in case of unbalanced three-phase loads authors will propose a structure composed by three single phase active filters. To begin is implemented the single-phase active filter whi...

Download PDF file
  • EP ID EP122901
  • DOI -
  • Views 105
  • Downloads 0

How To Cite

Maria Brojboiu, Virginia Ivanov, Andrei Savescu (2015).  About the Analytical Methods Applying for Fault Diagnosis of the Static Converters from the Electric Locomotive. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 39(39), 113-118. https://europub.co.uk/articles/-A-122901