ANALYSIS OF EFFECT OF EARTHQUAKE LOADS ON G+7 MULTI STOREY BUILDING USING REINFORCED CONCRETE SHEAR WALL AND REINFORCED MASONRY SHEAR WALL

Abstract

 Among many techniques (both passive and active) investigated for augmentation of heat transfer rates inside circular tubes, a wide range of inserts has been utilized, particularly when turbulent flow is considered. The inserts studied included coil wire inserts, brush inserts, mesh inserts, strip inserts, twisted tape inserts etc. Augmentation of convective heat transfer in internal flows with twisted tape inserts in tubes is a well-acclaimed technique employed in industrial practices. CFD investigations on enhancement of turbulent flow heat transfer with twisted tape inserts in a horizontal tube under forced convection with air flowing inside is carried out using ANSYS FLUNT. The variations of heat transfer coefficients; Nusselt number in the horizontal tube fitted with twisted tape is studied. A CFD investigation is conducted to study forced convection of fully developed turbulent flow through circular tube with twisted tape inserts. CFD solutions are obtained using commercial software ANSYS FLUENT v12.1. The working fluid in all cases is air.

Authors and Affiliations

Vinay Kumar Patel*

Keywords

Related Articles

STUDY OF PROS AND CONS IN THE EDUCATION SYSTEM USING BIG DATA

“Data is a precious thing and will last longer than the systems themselves.” – Tim Berners Lee, inventor of the World Wide Web. When Berners-Lee talked about data, he wouldn’t have imagined it growing to a gigantic size...

 FIVE POLE OPTIMUM DISTRIBUTED HIGH PASS MICROWAVE FILTER: DESIGN ANALYSIS AND SIMULATION ON MICROSTRIP AT 2.4 GHZ

 This paper presents a frequency responsive design of an optimum distributed high pass filter having a cutoff frequency fc = 2.4 GHz and a 0.1 dB ripple passband up to 10.4 GHz with Z0 = 50 ohm. This presents a...

 An Experimental Study of Message 

 Due to the continuous advancement in technology, mobile devices are playing important role in everyone’s day to day life. Security is the one of the biggest concern in different type of networks. Due to diversify...

 Study of Naghshe Rostam Fault in Geoelectrical Approach, Zagros Mountains

 One of the most common methods for investigation of subterraneous layers and condition of alluvium for studying faults is particular resistivity geo electrical surveying methods. The goal of this paper is detectin...

 Efficient iris Recognition System to Improve Performance Measure for live videos

 Iris recognition is regarded as the most reliable and accurate biometric identification system available. Iris substantiation is one of the most successful applications in video analysis and image processing. In t...

Download PDF file
  • EP ID EP137995
  • DOI -
  • Views 72
  • Downloads 0

How To Cite

Vinay Kumar Patel* (0).  ANALYSIS OF EFFECT OF EARTHQUAKE LOADS ON G+7 MULTI STOREY BUILDING USING REINFORCED CONCRETE SHEAR WALL AND REINFORCED MASONRY SHEAR WALL. International Journal of Engineering Sciences & Research Technology, 4(9), 400-408. https://europub.co.uk/articles/-A-137995